arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2212.01294physics.med-ph
收藏

使用深度学习进行脑PET-MR衰减校正:成人和临床儿科数据的方法验证

Brain PET-MR attenuation correction with deep learning: method validation in adult and clinical paediatric data

Siti N. Yaakub, Colm J. McGinnity, Eric Kerfoot, Ines Mérida, Katherine Beck, Eric Dunston, Marica Muffoletto, Suryava Bhattacharya, Ahmed Qureshi, Joel Dunn, J… 展开作者

Siti N. Yaakub, Colm J. McGinnity, Eric Kerfoot, Ines Mérida, Katherine Beck, Eric Dunston, Marica Muffoletto, Suryava Bhattacharya, Ahmed Qureshi, Joel Dunn, Jane MacKewn, Alexander Hammers

摘要:

用于基于磁共振的正电子发射断层成像衰减校正(PET-MR AC)的当前方法是耗时的,并且不如基于计算机断层成像(CT)的AC方法能够捕获个体间变异性和颅骨异常。已经提出了深度学习方法来从MR图像中生成伪CT,但这些方法尚未在大型临床队列中进行评估。在健康成人数据上训练的方法可能不适用于颅骨形态测量可能异常的临床队列,或颅骨往往更薄和更小的儿科数据。在这里,我们训练一个卷积神经网络的基础上的U-Net产生PET-MR AC的伪CT。我们对健康成人和接受临床PET扫描进行神经病学研究的患者的混合队列进行了网络训练。我们表明,我们的方法是能够产生伪CT的平均绝对误差(MAE)为100.4 $\pm$ 21.3 HU相比,参考CT,与Jaccard重叠系数为0.73 $\pm$ 0.07的颅骨掩模。与基于CT的线性衰减图相比,基于我们的伪CT的线性衰减图(相对MAE = 8.4 $\pm$ 2.1\%)比基于性能良好的基于多图谱的AC方法的线性衰减图(相对MAE = 13.1 $\pm$ 1.5\%)更准确。我们在临床儿科队列中改进了训练的网络。在儿科数据集中,MAE从使用现有网络时的174.7 $\pm$ 33.6 HU提高到迁移学习后的127.3 $\pm$ 39.9 HU,因此表明迁移学习可以提高儿科数据中的伪CT准确性。

英文摘要:

Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull abnormalities. Deep learning methods have been proposed to produce pseudo-CT from MR images, but these methods have not yet been evaluated in large clinical cohorts. Methods trained on healthy adult data may not work in clinical cohorts where skull morphometry may be abnormal, or in paediatric data where skulls tend to be thinner and smaller. Here, we train a convolutional neural network based on the U-Net to produce pseudo-CT for PET-MR AC. We trained our network on a mixed cohort of healthy adults and patients undergoing clinical PET scans for neurology investigations. We show that our method was able to produce pseudo-CT with mean absolute errors (MAE) of 100.4 $\pm$ 21.3 HU compared to reference CT, with a Jaccard overlap coefficient of 0.73 $\pm$ 0.07 in the skull masks. Linear attenuation maps based on our pseudo-CT (relative MAE = 8.4 $\pm$ 2.1\%) were more accurate than those based on a well-performing multi-atlas-based AC method (relative MAE = 13.1 $\pm$ 1.5\%) when compared with CT-based linear attenuation maps. We refined the trained network in a clinical paediatric cohort. MAE improved from 174.7 $\pm$ 33.6 HU when using the existing network to 127.3 $\pm$ 39.9 HU after transfer learning in the paediatric dataset, thus showing that transfer learning can improve pseudo-CT accuracy in paediatric data.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑