arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2211.15401physics.med-ph
收藏

对fMRI时间序列数据进行MP-PCA去噪会导致人为激活“扩散”

MP-PCA denoising of fMRI time-series data can lead to artificial activation "spreading"

Francisca F. Fernandes, Jonas L. Olesen, Sune N. Jespersen, Noam Shemesh

摘要:

MP-PCA去噪已成为MRI中去噪的首选方法,因为它提供了一个客观的阈值来将所需信号与不需要的热噪声分量分开。在啮齿动物中,线圈中的热噪声是一个重要的噪声源,可以降低fMRI激活映射的准确性。进一步混淆这个问题,供应商数据往往包含零填充和其他影响,可能违反MP-PCA假设。在这里,我们开发了一种方法去噪供应商的数据和评估激活“传播”所造成的MP-PCA去噪啮齿动物任务为基础的功能磁共振成像数据。在视觉刺激期间,使用常规多层和超快采集(分别为1秒和50毫秒的时间分辨率)从N = 3只小鼠获得数据。MP-PCA去噪产生64%和39%的SNR增益,并且当使用小[2 2]去噪窗口时,对于多层和超快数据,BOLD图中的傅立叶谱幅度(FSA)分别增加9%和7%。更大的窗口提供了更高的SNR和FSA增益,增加了空间范围的激活,可能代表或可能不代表真正的激活。模拟表明,MP-PCA去噪导致激活“扩散”,假阳性率增加,功能图由于主成分的局部“出血”而更平滑,并且基于Dice评分计算的用于改善功能图特异性的最佳去噪窗口取决于数据的tSNR和功能CNR。这种“扩散”效应也适用于最近提出的另一种低秩去噪方法(NORDIC)。我们的研究结果预示着大大提高空间和/或时间分辨率在未来的功能磁共振成像工作,同时考虑到低秩去噪方法的灵敏度/特异性权衡。

英文摘要:

MP-PCA denoising has become the method of choice for denoising in MRI since it provides an objective threshold to separate the desired signal from unwanted thermal noise components. In rodents, thermal noise in the coils is an important source of noise that can reduce the accuracy of activation mapping in fMRI. Further confounding this problem, vendor data often contains zero-filling and other effects that may violate MP-PCA assumptions. Here, we develop an approach to denoise vendor data and assess activation "spreading" caused by MP-PCA denoising in rodent task-based fMRI data. Data was obtained from N = 3 mice using conventional multislice and ultrafast acquisitions (1 s and 50 ms temporal resolution, respectively), during visual stimulation. MP-PCA denoising produced SNR gains of 64% and 39% and Fourier spectral amplitude (FSA) increases in BOLD maps of 9% and 7% for multislice and ultrafast data, respectively, when using a small [2 2] denoising window. Larger windows provided higher SNR and FSA gains with increased spatial extent of activation that may or may not represent real activation. Simulations showed that MP-PCA denoising causes activation "spreading" with an increase in false positive rate and smoother functional maps due to local "bleeding" of principal components, and that the optimal denoising window for improved specificity of functional mapping, based on Dice score calculations, depends on the data's tSNR and functional CNR. This "spreading" effect applies also to another recently proposed low-rank denoising method (NORDIC). Our results bode well for dramatically enhancing spatial and/or temporal resolution in future fMRI work, while taking into account the sensitivity/specificity trade-offs of low-rank denoising methods.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑