arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2211.04426physics.med-pheess.IV
收藏

使用3D- QALAS和Wave-CAIPI读数的时间有效、高分辨率3 T全脑定量弛豫测量

Time-efficient, High Resolution 3T Whole Brain Quantitative Relaxometry using 3D-QALAS with Wave-CAIPI Readouts

Jaejin Cho, Borjan Gagoski, Tae Hyung Kim, Fuyixue Wang, Daniel Nico Splitthoff, Wei-Ching Lo, Wei Liu, Daniel Polak, Stephen Cauley, Kawin Setsompop, P. Ellen Grant, Berkin Bilgic

摘要:

目的:脑组织弛豫特性的体积、高分辨率、定量映射受到长采集时间和信噪比(SNR)挑战的阻碍。这项研究首次将时间效率高的波CAIPI读数结合到3D量化中,使用具有T2准备脉冲(3D-QALAS)采集方案的交错Look-Quad采集序列,仅需3分钟即可在1.15 mm 3各向同性体素上实现全脑定量T1,T2和质子密度(PD)图。研究方法:Wave-CAIPI读数嵌入标准3D-QALAS编码方案中,在R= 3x 2的加速因子下实现全脑定量参数图(T1、T2和PD),同时由于g因子罚分而导致的SNR损失最小。定量参数图估计使用基于字典的映射算法,将反演效率和B1场的不均匀性。将使用加速协议的定量图与在ISMRM NIST体模和10名健康志愿者中使用R=2的GRAPPA加速从传统3D-QALAS序列获得的定量图进行定量比较。结果如下:当在ISMRM/NIST体模和10名健康志愿者中进行测试时,使用加速协议的定量图显示出与在RGRAPPA=2时从传统3D-QALAS获得的定量图的极好一致性。结论:3D-QALAS通过波CAIPI读数增强,可在3分钟内以R= 3x 2加速度在1.15 mm 3处实现时间效率高的全脑定量T1、T2和PD标测。当在NIST体模和10名健康志愿者上进行测试时,从加速波-CAIPI 3D-QALAS协议获得的定量图显示出与从标准3D-QALAS(R=2)协议获得的值非常相似的值,这暗示了所提出的方法的稳健性和可靠性。

英文摘要:

Purpose: Volumetric, high-resolution, quantitative mapping of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enabling full brain quantitative T1, T2 and proton density (PD) maps at 1.15 mm3 isotropic voxels in only 3 minutes. Methods: Wave-CAIPI readouts were embedded in the standard 3D-QALAS encoding scheme, enabling full brain quantitative parameter maps (T1, T2, and PD) at acceleration factors of R=3x2 with minimum SNR loss due to g-factor penalties. The quantitative parameter maps were estimated using a dictionary-based mapping algorithm incorporating inversion efficiency and B1 field inhomogeneity. The quantitative maps using the accelerated protocol were quantitatively compared against those obtained from conventional 3D-QALAS sequence using GRAPPA acceleration of R=2 in the ISMRM NIST phantom, and ten healthy volunteers. Results: When tested in both the ISMRM/NIST phantom and ten healthy volunteers, the quantitative maps using the accelerated protocol showed excellent agreement against those obtained from conventional 3D-QALAS at RGRAPPA=2. Conclusion: 3D-QALAS enhanced with wave-CAIPI readouts enables time-efficient, full brain quantitative T1, T2, and PD mapping at 1.15 mm3 in 3 minutes at R=3x2 acceleration. When tested on the NIST phantom and ten healthy volunteers, the quantitative maps obtained from the accelerated wave-CAIPI 3D-QALAS protocol showed very similar values to those obtained from the standard 3D-QALAS (R=2) protocol, alluding to the robustness and reliability of the proposed methods.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑