用于经颅聚焦超声手术的合成生成CT的评价

Evaluation of Synthetically Generated CT for use in Transcranial Focused Ultrasound Procedures

Vanderbilt University(范德堡大学)

Han Liu, Michelle K. Sigona, Thomas J. Manuel, Li Min Chen, Benoit M. Dawant, Charles F. Caskey

摘要:

经颅聚焦超声(tFUS)是一种治疗性超声方法,其通常在MRI引导下无创地将声音通过颅骨聚焦到小区域。CT成像用于估计个体颅骨之间的声学特性,以在tFUS程序期间实现有效聚焦,使患者暴露于潜在有害的辐射。一种无需CT就能估计颅骨声学参数的方法将是可取的。在这里,我们通过使用基于3D补丁的条件生成对抗网络(cGAN)从常规采集的T1加权MRI合成CT图像,并评估合成CT(sCT)图像用于tFUS治疗计划的性能。我们比较了sCT与使用Kranion进行tFUS规划的真实CT(rCT)图像的性能以及使用声学工具箱k-Wave进行模拟的性能。针对3种tFUS场景进行了模拟:1)无像差校正,2)使用Kranion计算的相位进行校正,以及3)使用时间反演计算的相移。根据Kranion,rCT和sCT之间的颅骨密度比、颅骨厚度和活性元素数量的Pearson相关系数分别为0.94、0.92和0.98。在20个靶点中,无相位校正时rCT和sCT之间的模拟峰值压力差异最大(12.4 $\pm$ 8.1%),有Kranion相位时最小(7.3 $\pm$ 6.0%)。对于所有模拟病例,rCT和sCT之间的峰值焦点位置之间的距离小于1.3 mm。真实和合成生成的头骨具有可比的图像相似性,头骨测量和声学模拟指标。我们的工作证明了用MR合成CT代替真实CT进行tFUS规划的可行性。源代码和带有训练模型的Docker图像可在www.example.com上获得

英文摘要:

Transcranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under MRI guidance. CT imaging is used to estimate the acoustic properties that vary between individual skulls to enable effective focusing during tFUS procedures, exposing patients to potentially harmful radiation. A method to estimate acoustic parameters in the skull without the need for CT would be desirable. Here, we synthesized CT images from routinely acquired T1-weighted MRI by using a 3D patch-based conditional generative adversarial network (cGAN) and evaluated the performance of synthesized CT (sCT) images for treatment planning with tFUS. We compared the performance of sCT to real CT (rCT) images for tFUS planning using Kranion and simulations using the acoustic toolbox, k-Wave. Simulations were performed for 3 tFUS scenarios: 1) no aberration correction, 2) correction with phases calculated from Kranion, and 3) phase shifts calculated from time-reversal. From Kranion, skull density ratio, skull thickness, and number of active elements between rCT and sCT had Pearson's Correlation Coefficients of 0.94, 0.92, and 0.98, respectively. Among 20 targets, differences in simulated peak pressure between rCT and sCT were largest without phase correction (12.4$\pm$8.1%) and smallest with Kranion phases (7.3$\pm$6.0%). The distance between peak focal locations between rCT and sCT was less than 1.3 mm for all simulation cases. Real and synthetically generated skulls had comparable image similarity, skull measurements, and acoustic simulation metrics. Our work demonstrates the feasibility of replacing real CTs with the MR-synthesized CT for tFUS planning. Source code and a docker image with the trained model are available at https://github.com/han-liu/SynCT_TcMRgFUS

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑