arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2210.14759stat.AP
收藏

低成本颗粒物传感器的退化分析

An analysis of degradation in low-cost particulate matter sensors

Priyanka deSouza, Karoline Barkjohn, Andrea Clements, Jenny Lee, Ralph Kahn, Ben Crawford, Patrick Kinney

摘要:

低成本传感器(LCS)越来越多地用于测量世界各地城市的细颗粒物(PM2.5)浓度。最常部署的LCS之一是PurpleAir,在美国部署了大约15,000个传感器。然而,传感器性能随时间的变化尚未得到很好的研究。重要的是要了解这些传感器的寿命,以确定何时应该更换它们,以及何时应该或不应该将这些设备的测量结果用于各种应用。本文通过利用以下事实填补了这一空白:1)每个PurpleAir传感器由两个相同的传感器组成,可以观察到它们的测量值之间的差异,以及2)在监管监视器的50米范围内有许多PurpleAir传感器,可以比较这两种仪器之间的测量值。我们提出了PurpleAir传感器的衍生退化结果,并评估这些结果如何随时间变化。平均而言,我们发现每个PurpleAir中的两个传感器不一致的“标记”测量值的数量在运行4年后会增加到4%。大约有2%的PurpleAir传感器出现永久性退化。永久退化的PurpleAir传感器的最大部分似乎位于炎热和潮湿的气候区,这表明该区域的传感器可能需要尽快更换。我们还发现,PurpleAir传感器的偏差,即校正后的PM2.5水平与相应参考测量值之间的差异,每年随时间变化-0.12 ug/m3(95%CI:-0.13 ug/m3,-0.11 ug/m3)。平均偏差在3.5年后急剧增加。气候带是退化结果与时间之间关系的重要修正因素。

英文摘要:

Low-cost sensors (LCS) are increasingly being used to measure fine particulate matter (PM2.5) concentrations in cities around the world. One of the most commonly deployed LCS is the PurpleAir with about 15,000 sensors deployed in the United States. However, the change in sensor performance over time has not been well studied. It is important to understand the lifespan of these sensors to determine when they should be replaced, and when measurements from these devices should or should not be used for various applications. This paper fills in this gap by leveraging the fact that: 1) Each PurpleAir sensor is comprised of two identical sensors and the divergence between their measurements can be observed, and 2) There are numerous PurpleAir sensors within 50 meters of regulatory monitors allowing for the comparison of measurements between these two instruments. We propose empirically-derived degradation outcomes for the PurpleAir sensors and evaluate how these outcomes change over time. On average, we find that the number of 'flagged' measurements, where the two sensors within each PurpleAir disagree, increases in time to 4 percent after 4 years of operation. Approximately, 2 percent of all PurpleAir sensors were permanently degraded. The largest fraction of permanently degraded PurpleAir sensors appeared to be in the hot and humid climate zone, suggesting that the sensors in this zone may need to be replaced sooner. We also find that the bias of PurpleAir sensors, or the difference between corrected PM2.5 levels and the corresponding reference measurements, changed over time by -0.12 ug/m3 (95% CI: -0.13 ug/m3, -0.11 ug/m3) per year. The average bias increases dramatically after 3.5 years. Climate zone is a significant modifier of the association between degradation outcomes and time.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑