电渗透法和等温脱附法测量氢扩散系数的相对有效性
On the relative efficacy of electropermeation and isothermal desorption approaches for measuring hydrogen diffusivity
摘要:
采用冷轧纯铁研究了电化学渗透(EP)法和等温脱附谱(ITDS)法测定氢扩散系数的相对有效性。从13个第一瞬态和8个第二瞬态EP实验,使用传统的滞后和突破时间的方法进行评估,确定的扩散系数进行比较,10 ITDS实验的结果。结果表明,第二EP瞬态和ITDS之间的平均扩散率是相似的,这是明显增加相对于第一EP瞬态。然而,ITDS实验的变异系数相对于第一和第二EP瞬变降低了2倍和3倍,证实了ITDS扩散率测量的可重复性提高。EP测量误差增加的来源进行了系统的评估,揭示了假设的电化学边界条件的EP实验的分析和解释的重要影响。
英文摘要:
The relative efficacy of electrochemical permeation (EP) and isothermal desorption spectroscopy (ITDS) methods for determining the hydrogen diffusivity is investigated using cold-rolled pure iron. The diffusivities determined from 13 first transient and 8 second transient EP experiments, evaluated using the conventional lag and breakthrough time methods, are compared to the results of 10 ITDS experiments. Results demonstrate that the average diffusivity is similar between the second EP transient and ITDS, which are distinctly increased relative to the first EP transient. However, the coefficient of variation for the ITDS experiments is reduced by 2 and 3-fold relative to the first and second EP transients, confirming the improved repeatability of ITDS diffusivity measurements. The source of the increased error in EP measurements is systematically evaluated, revealing an important influence of assumed electrochemical boundary conditions on the analysis and interpretation of EP experiments.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。