基于机器学习从惯性动作捕捉数据生成光学动作捕捉驱动的肌骨建模
Machine Learning for Optical Motion Capture-driven Musculoskeletal Modelling from Inertial Motion Capture Data
AI总结:
本文提出用FFNN与RNN等机器学习模型,将易获取的IMC数据映射为金标准OMC驱动的上肢肌骨模型输出,并在受试者暴露和未知设置下验证其高相关性。
摘要:
基于标记点的光学动作捕捉(OMC)系统及其相关的肌骨(MSK)建模预测,能够以非侵入方式获得关于体内关节和肌肉负荷的洞察,从而辅助临床决策。然而,OMC系统依赖实验室、价格昂贵,并且需要视线无遮挡。惯性动作捕捉(IMC)系统是被广泛使用的替代方案,具有便携、用户友好且成本相对较低的特点,但准确性较低。无论选择何种动作捕捉技术,都需要使用MSK模型来获得运动学和动力学输出;该工具计算成本高昂,而机器学习(ML)方法正越来越成熟地对其进行近似。本文提出一种ML方法,将实验记录的IMC数据映射到由(“金标准”)OMC输入数据计算得到的人体上肢MSK模型输出。本质上,我们的目标是从更容易获取的IMC数据预测更高质量的MSK输出。我们使用针对相同受试者同步采集的OMC和IMC数据来训练不同的ML架构,使其根据IMC测量值预测OMC驱动的MSK输出。具体而言,我们采用了多种神经网络(NN)架构,例如前馈神经网络(FFNN)和循环神经网络(RNN)(普通RNN、长短期记忆网络和门控循环单元),并在受试者暴露(SE)和受试者未知(SN)两种设置下,通过在超参数空间中进行穷举搜索来寻找最佳拟合模型。我们观察到FFNN和RNN模型具有相当的性能;对于留出测试数据,二者与期望的OMC驱动MSK估计值具有高度一致性(r平均值,SE,FFNN=0.90±0.19,r平均值,SE,RNN=0.89±0.17,r平均值,SN,FFNN=0.84±0.23,以及r平均值,SN,RNN=0.78±0.23)。利用ML模型将IMC输入映射为OMC驱动的MSK输出,可能有助于推动MSK建模从“实验室走向现场”。
英文摘要:
Marker-based Optical Motion Capture (OMC) systems and associated musculoskeletal (MSK) modelling predictions offer non-invasively obtainable insights into in vivo joint and muscle loading, aiding clinical decision-making. However, an OMC system is lab-based, expensive, and requires a line of sight. Inertial Motion Capture (IMC) systems are widely-used alternatives, which are portable, user-friendly, and relatively low-cost, although with lesser accuracy. Irrespective of the choice of motion capture technique, one needs to use an MSK model to obtain the kinematic and kinetic outputs, which is a computationally expensive tool increasingly well approximated by machine learning (ML) methods. Here, we present an ML approach to map experimentally recorded IMC data to the human upper-extremity MSK model outputs computed from ('gold standard') OMC input data. Essentially, we aim to predict higher-quality MSK outputs from the much easier-to-obtain IMC data. We use OMC and IMC data simultaneously collected for the same subjects to train different ML architectures that predict OMC-driven MSK outputs from IMC measurements. In particular, we employed various neural network (NN) architectures, such as Feed-Forward Neural Networks (FFNNs) and Recurrent Neural Networks (RNNs) (vanilla, Long Short-Term Memory, and Gated Recurrent Unit) and searched for the best-fit model through an exhaustive search in the hyperparameters space in both subject-exposed (SE) & subject-naive (SN) settings. We observed a comparable performance for both FFNN & RNN models, which have a high degree of agreement (ravg, SE, FFNN = 0.90+/-0.19, ravg, SE, RNN = 0.89+/-0.17, ravg, SN, FFNN = 0.84+/-0.23, & ravg, SN, RNN = 0.78+/-0.23) with the desired OMC-driven MSK estimates for held-out test data. Mapping IMC inputs to OMC-driven MSK outputs using ML models could be instrumental in transitioning MSK modelling from 'lab to field'.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。