arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2209.14217cs.CV
收藏

基于深度学习分割的低剂量腹部CT纵向变异性分析

Longitudinal Variability Analysis on Low-dose Abdominal CT with Deep Learning-based Segmentation

Vanderbilt University(范德堡大学);National Institute on Aging(美国国家衰老研究所)

Xin Yu, Yucheng Tang, Qi Yang, Ho Hin Lee, Riqiang Gao, Shunxing Bao, Ann Zenobia Moore, Luigi Ferrucci, Bennett A. Landman

摘要:

从心脏病到神经病学,代谢健康越来越多地被认为是一个风险因素,身体成分的有效评估对于定量表征这些关系至关重要。2D低剂量单层计算机断层扫描(CT)提供了一个高分辨率,定量组织图,虽然具有有限的视野。尽管在量化图像背景方面已经提出了许多潜在的分析,但对于低剂量单层CT纵向变异性与自动分割还没有全面的研究。我们使用基于监督深度学习的分割和无监督聚类方法研究了来自巴尔的摩老龄化纵向研究(BLSA)腹部数据集的1469名受试者的共计1816个切片。从1469名受试者中选出前两次扫描间隔两年的300名受试者,根据组织/器官大小和平均强度测量包括组内相关系数(ICC)和变异系数(CV)的纵向变异性。我们表明,我们的分割方法在纵向设置中是稳定的,对于13个目标腹部组织结构,Dice范围为0.821至0.962。我们观察到大多数器官的变异性高,ICC<0.5,肌肉、腹壁、脂肪和体膜区域的变异性低,平均ICC>0.8。我们发现器官的变异性与2D切片的横截面位置高度相关。我们的努力为定量探索和质量控制铺平了道路,以减少纵向分析中的不确定性。

英文摘要:

Metabolic health is increasingly implicated as a risk factor across conditions from cardiology to neurology, and efficiency assessment of body composition is critical to quantitatively characterizing these relationships. 2D low dose single slice computed tomography (CT) provides a high resolution, quantitative tissue map, albeit with a limited field of view. Although numerous potential analyses have been proposed in quantifying image context, there has been no comprehensive study for low-dose single slice CT longitudinal variability with automated segmentation. We studied a total of 1816 slices from 1469 subjects of Baltimore Longitudinal Study on Aging (BLSA) abdominal dataset using supervised deep learning-based segmentation and unsupervised clustering method. 300 out of 1469 subjects that have two year gap in their first two scans were pick out to evaluate longitudinal variability with measurements including intraclass correlation coefficient (ICC) and coefficient of variation (CV) in terms of tissues/organs size and mean intensity. We showed that our segmentation methods are stable in longitudinal settings with Dice ranged from 0.821 to 0.962 for thirteen target abdominal tissues structures. We observed high variability in most organ with ICC<0.5, low variability in the area of muscle, abdominal wall, fat and body mask with average ICC>0.8. We found that the variability in organ is highly related to the cross-sectional position of the 2D slice. Our efforts pave quantitative exploration and quality control to reduce uncertainties in longitudinal analysis.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑