arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2209.07237cs.CV
收藏

X射线冠状动脉造影图像序列前景提取和血管分割的鲁棒实现

Robust Implementation of Foreground Extraction and Vessel Segmentation for X-ray Coronary Angiography Image Sequence

Shanghai Jiao Tong University(上海交通大学);Shanghai Jiao Tong University School of Medicine(上海交通大学医学院);Ruijin Hospital, Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属瑞金医院);Research Institute of Pancreatic Diseases, Shanghai Jiao Tong University School of Medicine(上海交通大学医学院胰腺疾病研究所)

Zeyu Fu, Zhuang Fu, Chenzhuo Lu, Jun Yan, Jian Fei, Hui Han

摘要:

从X射线冠状动脉造影(XCA)图像序列中提取造影剂填充血管对于直观诊断和治疗具有重要的临床意义。在这项研究中,XCA图像序列被视为一个三维张量输入,血管层被视为一个稀疏张量,和背景层被视为一个低秩张量。利用张量核范数(TNN)最小化原理,提出了一种基于张量鲁棒主元分析(TRPCA)的血管层提取方法。此外,考虑到血管的不规则运动和周围无关组织的低频动态扰动,引入全变差(TV)正则化时空约束对前景层进行平滑处理。随后,对于对比度分布不均匀的血管层图像,采用两阶段区域生长(TSRG)方法进行血管增强和分割。采用全局阈值法预处理血管主干,采用Radon-Like特征(RLF)滤波器增强和连接断裂的小血管段,结合两个中间结果构建最终的二值血管掩模。在临床XCA图像序列和第三方数据集上对TV-TRPCA前景提取算法的可见性进行了评估,该算法能够有效提高常用血管分割算法的性能。在TV-TRPCA的基础上,进一步评价了TSRG算法的血管分割精度。定性和定量的结果验证了所提出的方法优于现有的国家的最先进的方法。

英文摘要:

The extraction of contrast-filled vessels from X-ray coronary angiography (XCA) image sequence has important clinical significance for intuitively diagnosis and therapy. In this study, the XCA image sequence is regarded as a 3D tensor input, the vessel layer is regarded as a sparse tensor, and the background layer is regarded as a low-rank tensor. Using tensor nuclear norm (TNN) minimization, a novel method for vessel layer extraction based on tensor robust principal component analysis (TRPCA) is proposed. Furthermore, considering the irregular movement of vessels and the low-frequency dynamic disturbance of surrounding irrelevant tissues, the total variation (TV) regularized spatial-temporal constraint is introduced to smooth the foreground layer. Subsequently, for vessel layer images with uneven contrast distribution, a two-stage region growing (TSRG) method is utilized for vessel enhancement and segmentation. A global threshold method is used as the preprocessing to obtain main branches, and the Radon-Like features (RLF) filter is used to enhance and connect broken minor segments, the final binary vessel mask is constructed by combining the two intermediate results. The visibility of TV-TRPCA algorithm for foreground extraction is evaluated on clinical XCA image sequences and third-party dataset, which can effectively improve the performance of commonly used vessel segmentation algorithms. Based on TV-TRPCA, the accuracy of TSRG algorithm for vessel segmentation is further evaluated. Both qualitative and quantitative results validate the superiority of the proposed method over existing state-of-the-art approaches.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑