恒温控制多区域建筑物的统计力学
Statistical Mechanics of Thermostatically Controlled Multi-Zone Buildings
摘要:
我们从统计力学的角度研究了与单个冷却单元聚集相关的集体现象和约束。这些单元被建模为恒温控制负荷(TCL),代表大型商业或住宅建筑中的区域。它们的能量输入是集中的,并由一个集体单元-空气处理单元(AHU)-控制,将冷空气输送到所有TCL,从而将它们耦合在一起。为了确定代表性的定性特征的AHU到TCL耦合,我们建立了一个现实的,但也足够简单的模型,并分析它在两个不同的制度:恒定电源温度(CST)和恒定功率输入(CPI)制度。在这两种情况下,我们中心的个人TCL温度的松弛动力学的统计稳定状态的分析。我们观察到,虽然在CST制度的动态是相对较快的,导致在控制设定点周围的所有TCL演变,CPI制度揭示了出现一个\emph{bi-modal probability distribution and two, possibly strongly separated, time scales}。我们观察到,在CPI制度的两种模式与所有的TCL是在相同的低温和高温状态,分别与偶尔(因此可能是罕见的)集体过渡模式之间类似的克莱默现象的统计物理。据我们所知,这种现象在多区域能源建筑工程的背景下被忽视了,即使它对建筑物中集中冷却系统的操作有直接影响。它告诉我们,需要在职业舒适度(与个人温度变化有关)和功率输出可预测性(DR计划的主要焦点)之间取得平衡。
英文摘要:
We study the collective phenomena and constraints associated with the aggregation of individual cooling units from a statistical mechanics perspective. These units are modelled as Thermostatically Controlled Loads (TCLs) and represent zones in a large commercial or residential building. Their energy input is centralized and controlled by a collective unit -- the Air Handling Unit (AHU) -- delivering cool air to all TCLs, thereby coupling them together. Aiming to identify representative qualitative features of the AHU-to-TCL coupling, we build a realistic but also sufficiently simple model and analyze it in two distinct regimes: the Constant Supply Temperature (CST) and the Constant Power Input (CPI) regimes. In both cases, we center our analysis on the relaxation dynamics of individual TCL temperatures to a statistically steady state. We observe that while the dynamics are relatively fast in the CST regime, resulting in all TCLs evolving around the control setpoint, the CPI regime reveals emergence of a \emph{bi-modal probability distribution and two, possibly strongly separated, time scales}. We observe that the two modes in the CPI regime are associated with all TCLs being in the same low and high-temperature states, respectively, with occasional (and therefore possibly rare) collective transition between the modes akin in the Kramer's phenomenon of statistical physics. To the best of our knowledge, this phenomenon was overlooked in the context of the multi-zone energy building engineering, even thought it has direct implications on the operations of centralized cooling systems in buildings. It teaches us that a balance needs to be struck between occupational comfort -- related to variations in the individual temperatures -- and power output predictability -- the main focus of the DR schemes.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。