本文提出AMP-PE方法,通过贝叶斯概率推断和近似消息传递实现QSM偶极子反演的自动参数估计与鲁棒磁化率图恢复,在模拟和体内数据上优于或媲美现有方法,避免了临床中视觉微调的主观性。

摘要:

目的:对于定量磁化率成像(QSM),临床环境中缺乏真实参考标准使得为偶极子反演确定合适参数变得困难。我们提出一种用于QSM的具有内置参数估计的概率贝叶斯方法,并纳入偶极子反演的非线性公式,以实现磁化率图的鲁棒恢复。理论:从贝叶斯角度看,图像小波系数近似稀疏,并用拉普拉斯分布建模。测量噪声用具有两个分量的高斯混合分布建模,其中第二个分量用于建模噪声离群值。通过概率推断,磁化率图和分布参数可以使用近似消息传递(AMP)联合恢复。方法:我们将所提出的带内置参数估计的AMP(AMP-PE)与最先进的L1-QSM、FANSI和MEDI方法在模拟和体内数据集上进行比较,并进行实验以探索AMP-PE的最佳设置。可复现代码可在https://github.com/EmoryCN2L/QSM_AMP_PE获取。结果:在模拟的Sim2Snr1数据集上,AMP-PE实现了最低的NRMSE、DFCM和最高的SSIM,而MEDI实现了最低的HFEN。在体内数据集上,AMP-PE具有鲁棒性,并使用估计的参数成功恢复磁化率图,而L1-QSM、FANSI和MEDI通常需要额外的视觉微调来选择或复核工作参数。结论:AMP-PE为QSM提供自动和自适应的参数估计,避免了视觉微调步骤的主观性,使其成为临床环境的理想选择。

英文摘要:

Purpose: For quantitative susceptibility mapping (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps. Theory: From a Bayesian perspective, the image wavelet coefficients are approximately sparse and modelled by the Laplace distribution. The measurement noise is modelled by a Gaussian-mixture distribution with two components, where the second component is used to model the noise outliers. Through probabilistic inference, the susceptibility map and distribution parameters can be jointly recovered using approximate message passing (AMP). Methods: We compare our proposed AMP with built-in parameter estimation (AMP-PE) to the state-of-the-art L1-QSM, FANSI and MEDI approaches on the simulated and in vivo datasets, and perform experiments to explore the optimal settings of AMP-PE. Reproducible code is available at https://github.com/EmoryCN2L/QSM_AMP_PE Results: On the simulated Sim2Snr1 dataset, AMP-PE achieved the lowest NRMSE, DFCM and the highest SSIM, while MEDI achieved the lowest HFEN. On the in vivo datasets, AMP-PE is robust and successfully recovers the susceptibility maps using the estimated parameters, whereas L1-QSM, FANSI and MEDI typically require additional visual fine-tuning to select or double-check working parameters. Conclusion: AMP-PE provides automatic and adaptive parameter estimation for QSM and avoids the subjectivity from the visual fine-tuning step, making it an excellent choice for the clinical setting.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑