针对声景评估的一种成本效益型耳机校准程序的评估

Assessment of a cost-effective headphone calibration procedure for soundscape evaluations

Nanyang Technological University(南洋理工大学)

Bhan Lam, Kenneth Ooi, Zhen-Ting Ong, Karn N. Watcharasupat, Trevor Wong, Woon-Seng Gan

AI总结:

本文评估了声景属性翻译项目中低成本OCV耳机校准程序,通过心理声学参数分析和36人受试者实验发现该方法在客观声学指标上存在较大偏差,并在约20%的刺激中引起显著感知差异,为进一步研究提供依据。

摘要:

为了提高声景标准的可用性和采用率,作为全球“声景属性翻译项目”(SATP)的一部分,提出了一种用于通过耳机再现音频刺激的低成本校准程序,以验证ISO/TS 12913-2:2018感知情感质量(PAQ)属性翻译。先前的一项初步研究显示,使用开路电压(OCV)校准程序时,与预期的等效连续A计权声压级($L_{\text{A,eq}}$)存在显著偏差。为了获得更全面的以人为本的视角,本文进一步从心理声学参数方面研究了OCV方法,包括相关的超限水平,以考虑来自SATP的相同27个刺激的时间效应。此外,进行了一项有36名参与者参加的受试者内实验,以检验OCV校准对ISO/TS 12913-2:2018中PAQ属性的影响。对客观指标的Bland-Altman分析显示,OCV方法在所有计权声级和响度指标以及粗糙度指标在\SI{5}{\\%}和\SI{10}{\\%}超限水平上均存在较大偏差。由于OCV方法,在约\SI{20}{\\%}的刺激中观察到了显著的感知差异,但这些差异与有偏差的声学指标之间没有明确的对应关系。由于样本量小且不配对,对客观和感知差异的解释需持谨慎态度,但这为进一步研究提供了依据。

英文摘要:

To increase the availability and adoption of the soundscape standard, a low-cost calibration procedure for reproduction of audio stimuli over headphones was proposed as part of the global ``Soundscape Attributes Translation Project'' (SATP) for validating ISO/TS~12913-2:2018 perceived affective quality (PAQ) attribute translations. A previous preliminary study revealed significant deviations from the intended equivalent continuous A-weighted sound pressure levels ($L_{\text{A,eq}}$) using the open-circuit voltage (OCV) calibration procedure. For a more holistic human-centric perspective, the OCV method is further investigated here in terms of psychoacoustic parameters, including relevant exceedance levels to account for temporal effects on the same 27 stimuli from the SATP. Moreover, a within-subjects experiment with 36 participants was conducted to examine the effects of OCV calibration on the PAQ attributes in ISO/TS~12913-2:2018. Bland-Altman analysis of the objective indicators revealed large biases in the OCV method across all weighted sound level and loudness indicators; and roughness indicators at \SI{5}{\%} and \SI{10}{\%} exceedance levels. Significant perceptual differences due to the OCV method were observed in about \SI{20}{\%} of the stimuli, which did not correspond clearly with the biased acoustic indicators. A cautioned interpretation of the objective and perceptual differences due to small and unpaired samples nevertheless provide grounds for further investigation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑