摘要:
本文提出了一种基于9自由度IMU的新型医疗设备,以帮助医疗专业人员在EEG检查中更精确地执行电极放置任务。该工具可以精确地告诉操作员是否正确遵循了10-20电极放置系统。手动任务非常重要且耗时,因为所有电极必须正确且非常精确地放置在患者头部。黄金标准过程是手动的,尽管可以应用几种医疗设备(开发到其他类型的医疗程序)来提高电极放置的精度,但它们仍然非常昂贵。所提出的医疗设备仅基于9自由度IMU的传感器和微处理器的处理能力,降低了设备的价格。此外,与基于红外视觉的系统相比,该装置的尺寸也减小了。所开发的系统包括可视化子系统,该可视化子系统使用特定工具3DSlicer将电极在患者虚拟头部中的位置可视化,以接收并可视化医疗器械指向患者头部时的3D姿态。初步结果表明了该装置的有效性。
英文摘要:
The paper proposes a novel medical device based on a 9 dof IMU to help health professionals performing more precisely the electrode placement task in EEG exams. The tool precisely tells the operator if the 10-20 electrode placement system is being correctly followed. The manual task is of major importance and time consuming, because all the electrodes must be correctly and very precisely placed in the head of the patient. The gold standard process is manual, and although several medical devices (developed to other types of medical procedures) can be applied to increase the precision of the electrode placement, they are still very expensive. The proposed medical device, based only on the sensors of a 9 dof IMU, and the processing capabilities of a microprocessor, diminish the price of the device. Moreover, the size of the apparatus is also diminished, when compared with infrared vision based systems. The developed system includes a visualization subsystem that visualises the position of the electrodes in a virtual head of the patient, using a specific tool, 3DSlicer, to receive and visualise the 3D pose of the medical device when point to the patient head. Preliminary results showed the validity of the proposed device.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。