F. Bock, N. Schmidt, P. K. Wang, N. Santiesteban, T. Horn, J. Huang, J. Lajoie, C. Munoz Camacho, J. K. Adkins, Y. Akiba, A. Albataineh, M. Amaryan, I. C. Arsene, C. Ayerbe Gayoso, J. Bae, X. Bai, M. D. Baker, M. Bashkanov, R. Bellwied, F. Benmokhtar, V. Berdnikov, J. C. Bernauer, W. Boeglin, M. Borysova, E. Brash, P. Brindza, W. J. Briscoe, M. Brooks, S. Bueltmann, M. H. S. Bukhari, A. Bylinkin, R. Capobianco, W. -C. Chang, Y. Cheon, K. Chen, K. -F. Chen, K. -Y. Cheng, M. Chiu, T. Chujo, Z. Citron, E. Cline, E. Cohen, T. Cormier, Y. Corrales Morales, C. Cotton, J. Crafts, C. Crawford, S. Creekmore, C. Cuevas, J. Cunningham, G. David, C. T. Dean, M. Demarteau, S. Diehl, N. Doshita, R. Dupre, J. M. Durham, R. Dzhygadlo, R. Ehlers, L. El Fassi, A. Emmert, R. Ent, C. Fanelli, R. Fatemi, S. Fegan, M. Finger, M. Finger, J. Frantz, M. Friedman, I. Friscic, D. Gangadharan, S. Gardner, K. Gates, F. Geurts, R. Gilman, D. Glazier, E. Glimos, Y. Goto, N. Grau, S. V. Greene, A. Q. Guo, L. Guo, S. K. Ha, J. Haggerty, T. Hayward, X. He, O. Hen, D. W. Higinbotham, M. Hoballah, A. Hoghmrtsyan, P. -h. J. Hsu, G. Huber, A. Hutson, K. Y. Hwang, C. E. Hyde, M. Inaba, T. Iwata, H. S. Jo, K. Joo, N. Kalantarians, G. Kalicy, K. Kawade, S. J. D. Kay, A. Kim, B. Kim, C. Kim, M. Kim, Y. Kim, Y. Kim, E. Kistenev, V. Klimenko, S. H. Ko, I. Korover, W. Korsch, G. Krintiras, S. Kuhn, C. -M. Kuo, T. Kutz, D. Lawrence, S. Lebedev, H. Lee, J. S. H. Lee, S. W. Lee, Y. -J. Lee, W. Li, W. B. Li, X. Li, X. Li, X. Li, X. Li, Y. T. Liang, S. Lim, C. -h. Lin, D. X. Lin, K. Liu, M. X. Liu, K. Livingston, N. Liyanage, W. J. Llope, C. Loizides, E. Long, R. -S. Lu, Z. Lu, W. Lynch, S. Mantry, D. Marchand, M. Marcisovsky, C. Markert, P. Markowitz, H. Marukyan, P. McGaughey, M. Mihovilovic, R. G. Milner, A. Milov, Y. Miyachi, A. Mkrtchyan, P. Monaghan, R. Montgomery, D. Morrison, A. Movsisyan, H. Mkrtchyan, A. Mkrtchyan, M. Murray, K. Nagai, J. Nagle, I. Nakagawa, C. Nattrass, D. Nguyen, S. Niccolai, R. Nouicer, G. Nukazuka, M. Nycz, V. A. Okorokov, S. Oresic, J. D. Osborn, C. O Shaughnessy, S. Paganis, Z. Papandreou, S. F. Pate, M. Patel, C. Paus, G. Penman, M. G. Perdekamp, D. V. Perepelitsa, H. Periera da Costa, K. Peters, W. Phelps, E. Piasetzky, C. Pinkenburg, I. Prochazka, T. Protzman, M. L. Purschke, J. Putschke, J. R. Pybus, R. Rajput-Ghoshal, J. Rasson, B. Raue, K. F. Read, K. Røed, R. Reed, J. Reinhold, E. L. Renner, J. Richards, C. Riedl, T. Rinn, J. Roche, G. M. Roland, G. Ron, M. Rosati, C. Royon, J. Ryu, S. Salur, R. Santos, M. Sarsour, J. Schambach, A. Schmidt, C. Schwarz, J. Schwiening, R. Seidl, A. Sickles, P. Simmerling, S. Sirca, D. Sharma, Z. Shi, T. -A. Shibata, C. -W. Shih, S. Shimizu, U. Shrestha, K. Slifer, K. Smith, D. Sokhan, R. Soltz, W. Sondheim, J. Song, J. Song, I. I. Strakovsky, P. Steinberg, P. Stepanov, J. Stevens, J. Strube, P. Sun, X. Sun, K. Suresh, V. Tadevosyan, W. -C. Tang, S. Tapia Araya, S. Tarafdar, L. Teodorescu, D. Thomas, A. Timmins, L. Tomasek, N. Trotta, R. Trotta, T. S. Tveter, E. Umaka, A. Usman, H. W. van Hecke, C. Van Hulse, J. Velkovska, E. Voutier, P. K. Wang, Q. Wang, Y. Wang, Y. Wang, D. P. Watts, N. Wickramaarachchi, L. Weinstein, M. Williams, C. -P. Wong, L. Wood, M. H. Wood, C. Woody, B. Wyslouch, Z. Xiao, Y. Yamazaki, Y. Yang, Z. Ye, H. D. Yoo, M. Yurov, N. Zachariou, W. A. Zajc, W. Zha, J. -L. Zhang, J. -X. Zhang, Y. Zhang, Y. -X. Zhao, X. Zheng, P. Zhuang

AI总结:

本文介绍了 ECCE 探测器量热系统的设计,通过三个电磁量热计和两个强子量热计覆盖 -3.7 至 3.8 赝快度范围,并评估其能量、位置分辨率、重建效率与粒子鉴别性能。

摘要:

我们描述了 ECCE 探测器设计中使用的量热计系统的设计与性能,该系统在充分考虑适当的技术与进度风险的前提下,以具有成本效益的方式实现整体性能指标。量热计系统由三个电磁量热计组成,覆盖 -3.7 至 3.8 的组合赝快度范围,并包含两个强子量热计。本文将介绍关键的量热计性能,包括能量与位置分辨率、重建效率以及粒子鉴别。

英文摘要:

We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.