Search for MeV Electron Recoils from Dark Matter in EXO-200
200 Collaboration, S. Al Kharusi, G. Anton, I. Badhrees, P. S. Barbeau, D. Beck, V. Belov, T. Bhatta, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chamb… 展开作者
200 Collaboration, S. Al Kharusi, G. Anton, I. Badhrees, P. S. Barbeau, D. Beck, V. Belov, T. Bhatta, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland, M. Coon, A. Craycraft, T. Daniels, L. Darroch, S. J. Daugherty, J. Davis, S. Delaquis, A. Der Mesrobian-Kabakian, R. DeVoe, J. Dilling, A. Dolgolenko, M. J. Dolinski, J. Echevers, W. Fairbank, D. Fairbank, J. Farine, S. Feyzbakhsh, P. Fierlinger, Y. S. Fu, D. Fudenberg, P. Gautam, R. Gornea, G. Gratta, C. Hall, E. V. Hansen, J. Hoessl, P. Hufschmidt, M. Hughes, A. Iverson, A. Jamil, C. Jessiman, M. J. Jewell, A. Johnson, A. Karelin, L. J. Kaufman, T. Koffas, R. Krücken, A. Kuchenkov, K. S. Kumar, Y. Lan, A. Larson, B. G. Lenardo, D. S. Leonard, G. S. Li, S. Li, Z. Li, C. Licciardi, Y. H. Lin, R. MacLellan, T. McElroy, T. Michel, B. Mong, D. C. Moore, K. Murray, O. Njoya, O. Nusair, A. Odian, I. Ostrovskiy, A. Perna, A. Piepke, A. Pocar, F. Retière, A. L. Robinson, P. C. Rowson, D. Ruddell, J. Runge, S. Schmidt, D. Sinclair, K. Skarpaas, A. K. Soma, V. Stekhanov, M. Tarka, S. Thibado, J. Todd, T. Tolba, T. I. Totev, R. H. M. Tsang, B. Veenstra, V. Veeraraghavan, P. Vogel, J. -L. Vuilleumier, M. Wagenpfeil, J. Watkins, L. J. Wen, U. Wichoski, G. Wrede, S. X. Wu, Q. Xia, D. R. Yahne, L. Yang, Y. -R. Yen, O. Ya. Zeldovich, T. Ziegler
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.
Inelastic Dark Matter and High-Energy Recoil Signatures in LZ
Department of Physics, Tsinghua University(清华大学物理系);Center for High Energy Physics, Peking University(北京大学高能物理中心);Department of Physics and Jockey Club Institute for Advanced Study, The Hong Kong University of Science and Technology(香港科技大学物理系及赛马会高等研究院)
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
MeV γ射线的光子成像由于背景大、图像不清晰而存在严重困难,其原因是探测中康普顿散射的物理参数确定不完整,缺乏反冲电子的方向信息。最近在MeV波段的主要飞行任务/仪器是康普顿伽马射线观测台/COMPTEL,它是康普顿照相机(CC),只探测到了$\sim30$持久源。它与GeV波段的$\sim$ 2000源形成鲜明对比。在这里,我们报告的电子跟踪康普顿相机(ETCC)的性能,并证明它有一个很好的潜力,以突破这一停滞在MeV的伽玛射线天文学。ETCC通过测量3-D反冲电子径迹提供康普顿散射的所有参数,然后恢复在CC中丢失的散射面偏差(SPD)。的能量损失率(dE/dx),其中CC无法测量,也得到了,并发现确实有助于减少背景下类似的空间条件下。因此,伽马检测的重要性提高了几倍。另一方面,SPD是定量确定点扩散函数(PSF)的必要条件。对于反冲电子的多次散射,SPD的分辨率提高到接近理论极限。有了这样一个良好确定的PSF,我们证明了第一次,它是可能的,以提供可靠的灵敏度在康普顿成像,而不利用优化算法。因此,这项研究突出了CC的根本弱点。相反,我们证明了ETCC在1 MeV下达到低于$1\times10^{-12}$ erg cm $^{-2}$ s $^{-1}$的灵敏度的可能性。
Investigating sub-MeV dark matter annihilation to neutrinos using direct detection experiments
Institute for Basic Science (IBS)(基础科学研究所);Technical University of Munich(慕尼黑工业大学);Chungnam National University(忠南国立大学);APJ Abdul Kalam Technological University(阿卜杜勒·卡拉姆技术大学)