arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2207.00089physics.ins-detcs.CVphysics.app-phq-bio.QM
收藏

基于无透镜全息术和深度学习的病毒噬斑快速无染色定量检测

Rapid and stain-free quantification of viral plaque via lens-free holography and deep learning

University of California, Los Angeles(加州大学洛杉矶分校);California NanoSystems Institute (CNSI), University of California, Los Angeles(加州大学洛杉矶分校加州纳米系统研究所);Texas A&M University(德克萨斯农工大学)

Tairan Liu, Yuzhu Li, Hatice Ceylan Koydemir, Yijie Zhang, Ethan Yang, Merve Eryilmaz, Hongda Wang, Jingxi Li, Bijie Bai, Guangdong Ma, Aydogan Ozcan

AI总结:

提出基于无透镜全息和深度学习的无染色病毒噬斑定量方法,显著缩短孵育时间,实现高检出率与特异性,并扩大检测动态范围。

摘要:

我们提出了一种利用无透镜全息成像和深度学习进行快速、无染色的定量病毒噬斑检测方法。这种经济高效、紧凑且自动化的设备显著缩短了传统噬斑检测所需的孵育时间,同时保留了其相对于其他病毒定量方法的优势。该设备以无标记方式捕获每个测试孔中物体约0.32 Giga-pixel/小时的相位信息,覆盖约30x30 mm^2的面积,完全消除了染色步骤。我们使用水疱性口炎病毒(VSV)、单纯疱疹病毒(HSV-1)和脑心肌炎病毒(EMCV)证明了这种计算方法的有效性。利用神经网络,该无染色设备在孵育后仅5小时即可自动检测到由VSV病毒复制引起的首次细胞裂解事件,并在<20小时内实现对VSV噬斑形成单位(PFUs)>90%的检出率,且特异性为100%,相比传统至少需要48小时的噬斑检测方法,节省了大量时间。同样,该无染色设备将HSV-1所需的孵育时间缩短了约48小时,EMCV缩短了约20小时,均实现了>90%的检出率和100%的特异性。我们还证明了这种数据驱动的噬斑检测方法能够量化细胞单层的感染面积,在病毒浓度动态范围比标准病毒噬斑检测方法大10倍的情况下,自动进行PFUs和病毒感染面积的计数与定量。这种紧凑、低成本、自动化的PFU定量设备可广泛应用于病毒学研究、疫苗开发和临床应用。

英文摘要:

We present a rapid and stain-free quantitative viral plaque assay using lensfree holographic imaging and deep learning. This cost-effective, compact, and automated device significantly reduces the incubation time needed for traditional plaque assays while preserving their advantages over other virus quantification methods. This device captures ~0.32 Giga-pixel/hour phase information of the objects per test well, covering an area of ~30x30 mm^2, in a label-free manner, eliminating staining entirely. We demonstrated the success of this computational method using vesicular stomatitis virus (VSV), herpes simplex virus (HSV-1) and encephalomyocarditis virus (EMCV). Using a neural network, this stain-free device automatically detected the first cell lysing events due to the VSV viral replication as early as 5 hours after the incubation, and achieved >90% detection rate for the VSV plaque-forming units (PFUs) with 100% specificity in <20 hours, providing major time savings compared to the traditional plaque assays that take at least 48 hours. Similarly, this stain-free device reduced the needed incubation time by ~48 hours for HSV-1 and ~20 hours for EMCV, achieving >90% detection rate with 100% specificity. We also demonstrated that this data-driven plaque assay offers the capability of quantifying the infected area of the cell monolayer, performing automated counting and quantification of PFUs and virus-infected areas over a 10-fold larger dynamic range of virus concentration than standard viral plaque assays. This compact, low-cost, automated PFU quantification device can be broadly used in virology research, vaccine development, and clinical applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑