Integral Field Spectrographs (IFS) often require non-trivial calibration techniques to process raw data. The OH Suppressing InfraRed Imaging Spectrograph (OSIRIS) at the W. M. Keck Observatory is a lenslet-based IFS that requires precise methods to associate the flux on the detector with both a wavelength and a position on the detector. During calibration scans, a single column lenslet mask is utilized to keep light from adjacent lenslet columns separate from the primary lenslet column, in order to uniquely determine spectral response of individual lenslets on the detector. Despite employing a single column lenslet mask, an issue associated with such calibration schemes may occur when light from adjacent masked lenslet columns leaks into the primary lenslet column. Incorrectly characterizing the flux due to additional light in the primary lenslet column results in one form of crosstalk between lenslet columns, which most clearly manifest as non-physical artifacts in the spectral dimension of the reduced data. We treat the problem of potentially blended calibration scans as a source separation problem and implement Non-negative Matrix Factorization (NMF) as a way to separate blended calibration scan spectra. After applying NMF to calibration scan data, extracted spectra from calibration scans show reduced crosstalk of up to 26.7$\pm$0.5$\%$ while not adversely impacting the signal-to-noise ratio. Additionally, we determined the optimal number of calibration scans per lenslet column needed to create NMF factors, finding that greatest reduction crosstalk occurs when NMF factors are created using one calibration scan per lenslet column.
Design of SCALES: A 2-5 Micron Coronagraphic Integral Field Spectrograph for Keck Observatory
介绍了正在为凯克天文台建造的一台新的2-5微米日冕积分场摄谱仪SCALES(Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy)的设计。SCALES能够实现低分辨率(R~50)光谱学,以及中分辨率(R~ 4,000)光谱学,目的是发现和表征在热红外线中最亮的冷系外行星。此外,SCALES还有一个12 x12”视场成像仪,将用于凯克的一般自适应光学科学。我们介绍了SCALES的规格、科学案例、总体设计以及对其预期性能的模拟。此外,我们目前的进展采购,制造和测试长交货期的组件。
PypeIt: The Python Spectroscopic Data Reduction Pipeline
PypeIt是一个Python软件包,用于半自动化天文光谱数据的简化。它的算法建立在开发人员数十年来对先前数据简化管道的开发基础上(Bernstein,Burles,& Prochaska,2015; Bochanski et al.,2009年)。简化过程--包括输入参数和可用功能的完整列表--作为Read the Reader托管的在线文档提供,该文档定期更新。(https://pypeit.readthedocs.io/en/latest/)。版本v1.0.3提供以下光谱仪:Gemini/GNIRS,Gemini/GMOS,Gemini/FLAMINGOS 2,Lick/Kast,Magellan/MGE,Magellan/Fire,MDM/OSMOS,Keck/DEIMOS(600ZD,830G,1200G),Keck/LRIS,Keck/MOSFIRE(J和Y光栅测试),Keck/NIRES,Keck/NIRSPEC(低色散)、LBT/Luci-I、Luci-II、LBT/MODS(beta)、NOT/ALFOSC(grism4)、VLT/X-Shooter(VIS、NIR)、VLT/FORS2(300I、300V)、WHT/ISIS。
CWITools: A Python3 Data Analysis Pipeline for the Cosmic Web Imager Instruments
Palomar Cosmic Web Imager(PCWI)和Keck Cosmic Web Imager(KCWI)是Palomar天文台的Hale 5米望远镜和W. M. Keck Observatory天文台近年来,这些仪器越来越多地用于进行调查工作,特别是在高红移的环星系和星系间介质的重点。从三维IFU数据中提取微弱信号是一项复杂的任务,如果没有适当的工具,对于大样本可能会变得非常困难。我们提出了CWITools,一个用Python 3编写的软件包,用于分析PCWI和KCWI数据。CWITools旨在提供标准仪器数据简化管道的输出与科学产品之间的管道,如表面亮度图,光谱,速度图以及各种相关模型和测量。虽然该软件包是专门为PCWI和KCWI数据设计的,但该软件包是开源的,可以适应任何三维积分场光谱数据。在这里,我们将描述这个管道,各个步骤背后的方法,并提供示例应用程序。