arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2206.04070astro-ph.IM
收藏

用非负矩阵分解改进Keck OSIRIS积分场谱仪的定标

Using Non-Negative Matrix Factorization to Improve Calibration of the Keck OSIRIS Integral Field Spectrograph

Katelyn Horstman, Michael P. Fitzgerald, James E. Lyke, Sherry C. C. Yeh, Devin S. Chu

摘要:

积分场光谱仪(IFS)通常需要非平凡的校准技术来处理原始数据。OH抑制红外成像光谱仪(OSIRIS)是在美国华盛顿大学研制的。M.凯克天文台是一个基于小透镜的IFS,需要精确的方法将探测器上的通量与探测器上的波长和位置相关联。在校准扫描期间,利用单列小透镜掩模来保持来自相邻小透镜列的光与主小透镜列分离,以便唯一地确定检测器上的各个小透镜的光谱响应。尽管采用单列小透镜掩模,但是当来自相邻的被掩模的小透镜列的光泄漏到主小透镜列中时,可能发生与这种校准方案相关联的问题。由于主小透镜列中的附加光而不正确地表征通量导致小透镜列之间的一种形式的串扰,其最清楚地表现为减少的数据的光谱维度中的非物理伪影。我们将潜在混合校准扫描的问题视为源分离问题,并实施非负矩阵分解(NMF)作为分离混合校准扫描光谱的一种方式。在将NMF应用于校准扫描数据之后,从校准扫描提取的光谱示出了高达26.7 $\pm$ ± 0.5 $\%$的降低的串扰,同时没有不利地影响信噪比。此外,我们确定了创建NMF因子所需的每个小透镜列的校准扫描的最佳数量,发现当使用每个小透镜列一次校准扫描创建NMF因子时,发生最大的串扰减少。

英文摘要:

Integral Field Spectrographs (IFS) often require non-trivial calibration techniques to process raw data. The OH Suppressing InfraRed Imaging Spectrograph (OSIRIS) at the W. M. Keck Observatory is a lenslet-based IFS that requires precise methods to associate the flux on the detector with both a wavelength and a position on the detector. During calibration scans, a single column lenslet mask is utilized to keep light from adjacent lenslet columns separate from the primary lenslet column, in order to uniquely determine spectral response of individual lenslets on the detector. Despite employing a single column lenslet mask, an issue associated with such calibration schemes may occur when light from adjacent masked lenslet columns leaks into the primary lenslet column. Incorrectly characterizing the flux due to additional light in the primary lenslet column results in one form of crosstalk between lenslet columns, which most clearly manifest as non-physical artifacts in the spectral dimension of the reduced data. We treat the problem of potentially blended calibration scans as a source separation problem and implement Non-negative Matrix Factorization (NMF) as a way to separate blended calibration scan spectra. After applying NMF to calibration scan data, extracted spectra from calibration scans show reduced crosstalk of up to 26.7$\pm$0.5$\%$ while not adversely impacting the signal-to-noise ratio. Additionally, we determined the optimal number of calibration scans per lenslet column needed to create NMF factors, finding that greatest reduction crosstalk occurs when NMF factors are created using one calibration scan per lenslet column.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑