冻结条件下同轴式地换热器取热的数值模拟
Numerical simulation of heat extraction by a coaxial ground heat exchanger under freezing conditions
摘要:
本文提出了一种新的考虑土壤水分冻结的同轴式浅层地下换热器内部及周围分层土壤中传热的有限差分模型。数值模拟了换热器的三种运行模式:稳态模式、瞬态模式和受控模式。在静止模式中,计算载热流体出口温度对换热器参数变化的敏感度的估计。在所有模式中,都密切关注在考虑和不考虑地面水分冻结的情况下计算的流体负温度下结果的差异。结果表明,这种差异,所造成的零幕效应,可以从10%的稳定模式中的控制模式中的35%。
英文摘要:
A new finite-difference model of heat transfer inside a shallow coaxial ground heat exchanger and in the surrounding layered soil is presented, taking into account the freezing of ground moisture. Three modes of heat exchanger operation are numerically simulated: stationary mode, transient mode and controlled mode. In the stationary mode, estimates of the sensitivity of the heat carrier fluid outlet temperature to changes in the heat exchanger parameters are calculated. In all modes, close attention is paid to demonstrating the difference in the results at a negative temperature of the fluid, calculated with and without taking into account the freezing of ground moisture. It is shown that this difference, caused by the zero-curtain effect, can range from 10% in the stationary mode to 35% in the control mode.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。