微重力条件下大直径脉动热管的实验分析与瞬态数值模拟

Experimental analysis and transient numerical simulation of a large diameter pulsating heat pipe in microgravity conditions

Mauro Abela, Mauro Mameli, Vadim Nikolayev, Sauro Filippeschi

摘要:

一个多参数的瞬态数值模拟的启动大直径脉动热管(PHP)专门设计用于未来的实验在国际空间站(ISS)的抛物线飞行活动期间获得的结果相比,由欧洲航天局支持。由于通道直径大于正常重力下的毛细管极限,因此这种装置在地面上表现为回路热虹吸管,在失重条件下表现为PHP;因此,微重力环境对于脉动模式是强制性的。由于抛物线飞行期间微重力持续时间短,数据仅涉及装置的瞬时启动行为。文献中最全面的模型之一,即内部一维瞬态代码CASCO(Code Avanc{é} de Simulation du Caloduc Oscillant的法文缩写:高级PHP模拟代码英文),已配置的几何,拓扑,材料特性和热边界条件来模拟实验装置,并在时间上同时进行数值计算和实验结果的比较。多个参数的演变:管壁温度、压力,以及在可能的情况下,液体塞的速度、长度和温度分布。对于不同的输入功率,仿真结果与实验结果基本一致。温度预测的最大偏差为7%。定性地捕捉了压力变化趋势以及液塞速度、长度和温度分布。该模型还显示了捕获热载荷施加后流体压力开始振荡的瞬间的能力,这是正确设计将在国际空间站上测试的工程模型的基本信息。我们还揭示了存在强的液体温度梯度附近的液体塞的两端实验和模拟。最后,给出了微重力条件下大直径PHP稳定运行的理论预测。结果表明,在输入功率为185 W时,系统在1 min后就能达到稳态,并能保持稳定运行。

英文摘要:

A multi-parametric transient numerical simulation of the start-up of a large diameter Pulsating Heat Pipe (PHP) specially designed for future experiments on the International Space Station (ISS) are compared to the results obtained during a parabolic flight campaign supported by the European Space Agency. Since the channel diameter is larger than the capillary limit in normal gravity, such a device behaves as a loop thermosyphon on ground and as a PHP in weightless conditions; therefore, the microgravity environment is mandatory for pulsating mode. Because of a short duration of microgravity during a parabolic flight, the data concerns only the transient start-up behavior of the device. One of the most comprehensive models in the literature, namely the in-house 1-D transient code CASCO (French acronym for Code Avanc{é} de Simulation du Caloduc Oscillant: Advanced PHP Simulation Code in English), has been configured in terms of geometry, topology, material properties and thermal boundary conditions to model the experimental device.The comparison between numerical and experimental results is performed simultaneously on the temporal evolution of multiple parameters: tube wall temperature, pressure and, wherever possible, velocity of liquid plugs, their length and temperature distribution within them. The simulation results agree with the experiment for different input powers. Temperatures are predicted with a maximum deviation of 7%. Pressure variation trend is qualitatively captured as well as the liquid plug velocity, length and temperature distribution. The model also shows the ability of capturing the instant when the fluid pressure begins to oscillate after the heat load is supplied, which is a fundamental information for the correct design of the engineering model that will be tested on the ISS. We also reveal the existence of strong liquid temperature gradients near the ends of liquid plugs both experimentally and by simulation. Finally, a theoretical prediction of the stable functioning of a large diameter PHP in microgravity is given. Results show that the system provided with an input power of 185W should be able to reach the steady state after 1min and maintain a stable operation from then on.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑