FiN:一个智能电网和电力线通信数据集

FiN: A Smart Grid and Power Line Communication Dataset

Christoph Balada, Sheraz Ahmed, Andreas Dengel, Max Bondorf, Nikolai Hopfer, Markus Zdrallek

摘要:

低压网络日益复杂,对电网的可靠和故障安全运行提出了越来越大的挑战。其原因包括越来越分散的能源生产(光伏系统,风力发电等)。以及新型消费者的出现(电动汽车、家用电力存储等)。与此同时,低压电网在很大程度上没有受到监控,当地的电力故障有时很难发现。为了克服这一点,电力线通信(PLC)已成为一个潜在的解决方案,可靠的监测低压电网。除了建立通信基础设施外,PLC还可以评估电缆本身,以及基于信噪比(SNR)的单个电缆分配器之间的连接质量。因此,大规模PLC基础设施的推出不仅确保了通信,而且还引入了监控整个网络的工具。为了评估这些数据的潜力,作为Fühler-im-Netz项目的一部分,我们在一个人口约15万的德国城市的三个不同区域安装了38个PLC调制解调器。在22个月的时间内,每一刻钟生成相邻PLC调制解调器之间每个连接的SNR频谱。%,并且每分钟测量电压。这种真实世界PLC数据的可用性为应对未来智能电网中日益复杂的挑战开辟了新的可能性。本文提供了一个详细的数据生成分析,并介绍了如何在电网正常运行期间收集数据。此外,我们提出了常见的异常,影响和趋势,可以在PLC数据中观察到每日,每周或季节性水平。最后,我们讨论了潜在的用例,并以电缆段的远程检测为例。

英文摘要:

The increasing complexity of low-voltage networks poses a growing challenge for the reliable and fail-safe operation of electricity grids. The reasons for this include an increasingly decentralized energy generation (photovoltaic systems, wind power, etc.) and the emergence of new types of consumers (e-mobility, domestic electricity storage, etc.). At the same time, the low-voltage grid is largely unmonitored and local power failures are sometimes hard to detect. To overcome this, power line communication (PLC) has emerged as a potential solution for reliable monitoring of the low-voltage grid. In addition to establishing a communication infrastructure, PLC also offers the possibility of evaluating the cables themselves, as well as the connection quality between individual cable distributors based on their Signal-to-Noise Ratio (SNR). The roll-out of a large-scale PLC infrastructure therefore not only ensures communication, but also introduces a tool for monitoring the entire network. To evaluate the potential of this data, we installed 38 PLC modems in three different areas of a German city with a population of about 150,000 as part of the Fühler-im-Netz project. Over a period of 22 months, an SNR spectrum of each connection between adjacent PLC modems was generated every quarter of an hour. % and the voltage was measured every minute. The availability of this real-world PLC data opens up new possibilities to react to the increasingly complex challenges in future smart grids. This paper provides a detailed analysis of the data generation and describes how the data was collected during normal operation of the electricity grid. In addition, we present common anomalies, effects, and trends that could be observed in the PLC data at daily, weekly, or seasonal levels. Finally, we discuss potential use cases and the remote inspection of a cable section is highlighted as an example.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑