AutoCOR:TKA术后膝关节外侧X线片上的自主髁偏移比计算器

AutoCOR: Autonomous Condylar Offset Ratio Calculator on TKA-Postoperative Lateral Knee X-ray

Istanbul Medipol University(伊斯坦布尔梅迪波尔大学)

Gulsade Rabia Cakmak, Ibrahim Ethem Hamamci, Mehmet Kursat Yilmaz, Reda Alhajj, Ibrahim Azboy, Mehmet Kemal Ozdemir

摘要:

全膝关节置换术(TKA)术后关节活动度是决定其疗效的重要因素之一。尽管文献中对膝关节屈曲范围与后髁偏移(PCO)之间的相关性存在争议,但PCO在TKA评价中仍具有重要意义。由于PCO测量的局限性,引入了两个新的参数,后髁偏移比(PCOR)和前髁偏移比(ACOR)。目前,在侧位平片上计算PCOR和ACOR是由骨科医生手动完成的。在这方面,我们开发了一个软件,AutoCOR,自主计算PCOR和ACOR,利用无监督机器学习算法(k均值聚类)和数字图像处理技术。软件AutoCOR能够在真实的术后侧位常规X线片上检测股骨干的前/后缘点和前/后皮质。为了测试该算法,使用了来自伊斯坦布尔Kosuyolu Medipol医院数据库的50张术后真实侧位X线片(32名患者)。软件结果中的平均PCOR为0.984(SD 0.235),真实值中的平均PCOR为0.972(SD 0.164)。它显示了软件和地面真值之间的强且显著的相关性(Pearson r=0.845 p<0.0001)。软件结果中的平均ACOR为0.107(SD 0.092),真实值中的平均ACOR为0.107(SD 0.070)。它显示软件和地面实况值之间的中度和显著相关性(Spearman rs=0.519 p=0.0001412)。我们认为AutoCOR是一个有用的工具,可以在临床实践中使用。

英文摘要:

The postoperative range of motion is one of the crucial factors indicating the outcome of Total Knee Arthroplasty (TKA). Although the correlation between range of knee flexion and posterior condylar offset (PCO) is controversial in the literature, PCO maintains its importance on evaluation of TKA. Due to limitations on PCO measurement, two novel parameters, posterior condylar offset ratio (PCOR) and anterior condylar offset ratio (ACOR), were introduced. Nowadays, the calculation of PCOR and ACOR on plain lateral radiographs is done manually by orthopedic surgeons. In this regard, we developed a software, AutoCOR, to calculate PCOR and ACOR autonomously, utilizing unsupervised machine learning algorithm (k-means clustering) and digital image processing techniques. The software AutoCOR is capable of detecting the anterior/posterior edge points and anterior/posterior cortex of the femoral shaft on true postoperative lateral conventional radiographs. To test the algorithm, 50 postoperative true lateral radiographs from Istanbul Kosuyolu Medipol Hospital Database were used (32 patients). The mean PCOR was 0.984 (SD 0.235) in software results and 0.972 (SD 0.164) in ground truth values. It shows strong and significant correlation between software and ground truth values (Pearson r=0.845 p<0.0001). The mean ACOR was 0.107 (SD 0.092) in software results and 0.107 (SD 0.070) in ground truth values. It shows moderate and significant correlation between software and ground truth values (Spearman's rs=0.519 p=0.0001412). We suggest that AutoCOR is a useful tool that can be used in clinical practice.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑