arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2204.02866physics.ins-dethep-exnucl-ex
收藏

聚萘二甲酸乙二醇酯对中子的光响应

Light Response of Poly(ethylene 2,6-napthalate) to Neutrons

Brennan Hackett, Richard deBoer, Yuri Efremenko, Michael Febbraro, Jason Nattress, Dan Bardayan, Chevelle Boomershine, Kristyn Brandenburg, Stefania Dede, Josep… 展开作者

Brennan Hackett, Richard deBoer, Yuri Efremenko, Michael Febbraro, Jason Nattress, Dan Bardayan, Chevelle Boomershine, Kristyn Brandenburg, Stefania Dede, Joseph Derkin, Ruoyu Fang, Adam Fritsch, August Gula, Gyurky Gyorgy, Gula Hamad, Yenuel Jones-Alberty, Beka Kelmar, Khachatur Manukyan, Miriam Matney, John McDonaugh, Shane Moylan, Patrick O'Malley, Shahina Shahina, Nisha Singh

AI总结:

本文测量了PEN材料对三种中子源的淬灭因子,通过同时分析得到Birk因子和闪烁效率,评估其作为低本底实验材料的可行性。

摘要:

随着吨级、稀有事件和低温探测器的开发,对低本底活性材料的需求日益增加。聚萘二甲酸乙二醇酯(PEN)因其坚固的结构特性和在蓝光波段的闪烁发光而被考虑用于这些应用。为评估该材料,已测量了PEN的辐射发光特性。本文介绍了使用三种不同中子源对PEN淬灭因子的测量结果:来自$^{252}$Cf自发裂变发射的中子、DD发生器产生的中子,以及来自$^{13}$C($\alpha$,n)$^{16}$O和$^{7}$Li(p,n)$^{7}$Be核反应发射的中子。裂变源使用飞行时间法确定中子能量,而核反应产生的中子能量则通过薄靶和反应运动学确定。通过对三种不同来源获得的数据进行同时分析,发现Birk因子和闪烁效率分别为$kB = 0.12 \pm 0.01$ mm MeV$^{-1}$和$S = 1.31\pm0.09$ MeV$_{ee}$ MeV$^{-1}$。利用这些参数,可以评估PEN作为大规模低本底物理实验可行材料的适用性。

英文摘要:

There is increasing necessity for low background active materials as ton-scale, rare-event and cryogenic detectors are developed. Poly(ethylene-2,6-naphthalate) (PEN) has been considered for these applications because of its robust structural characteristics, and its scintillation light in the blue wavelength region. Radioluminescent properties of PEN have been measured to aid in the evaluation of this material. In this article we present a measurement of PEN's quenching factor using three different neutron sources; neutrons emitted from spontaneous fission in $^{252}$Cf, neutrons generated from a DD generator, and neutrons emitted from the $^{13}$C($α$,n)$^{16}$O and the $^{7}$Li(p,n)$^{7}$Be nuclear reactions. The fission source used time-of-flight to determine the neutron energy, and the neutron energy from the nuclear reactions was defined using thin targets and reaction kinematics. The Birk's factor and scintillation efficiency were found to be $kB = 0.12 \pm 0.01$ mm MeV$^{-1}$ and $S = 1.31\pm0.09$ MeV$_{ee}$ MeV$^{-1}$ from a simultaneous analysis of the data obtained from the three different sources. With these parameters, it is possible to evaluate PEN as a viable material for large-scale, low background physics experiments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑