arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2203.03725astro-ph.IMphysics.atom-ph
收藏

Ne、CO$_2$和SF$_6$软X射线跃迁能量的新基准:为实现ppm精度铺平道路

A new benchmark of soft X-ray transition energies of Ne, CO$_2$, and SF$_6$: paving a pathway towards ppm accuracy

J. Stierhof, S. Kühn, M. Winter, P. Micke, R. Steinbrügge, C. Shah, N. Hell, M. Bissinger, M. Hirsch, R. Ballhausen, M. Lang, C. Gräfe, S. Wipf, R. Cumbee, G. L… 展开作者

J. Stierhof, S. Kühn, M. Winter, P. Micke, R. Steinbrügge, C. Shah, N. Hell, M. Bissinger, M. Hirsch, R. Ballhausen, M. Lang, C. Gräfe, S. Wipf, R. Cumbee, G. L. Betancourt-Martinez, S. Park, J. Niskanen, M. Chung, F. S. Porter, T. Stöhlker, T. Pfeifer, G. V. Brown, S. Bernitt, P. Hansmann, J. Wilms, J. R. Crespo López-Urrutia, M. A. Leutenegger

AI总结:

为提升X射线光谱标定精度,本文在BESSY II同步辐射装置上同时测量Ne、CO₂和SF₆的光离子产额谱及Polar-X EBIT中类He离子荧光,并以高精度从头计算为基准,评估统计与系统不确定度,指出结合相对能量校准技术有望将不确定度降至1–10 meV。

摘要:

正确解释高分辨率X射线光谱的一个关键要求是跃迁能量具有高准确度和高精度。我们通过在BESSY II同步辐射设施中测量Ne、CO$_2$和SF$_6$气体的光离子产额谱,并同时测量Polar-X EBIT中产生的类He离子的1s-np荧光发射,研究了这些气体的K壳层特征。这些离子中跃迁的精确从头计算为校准提供了基础。虽然CO$_2$的结果与先前的测量结果吻合良好,但SF$_6$光谱似乎偏移了约0.5 eV,大约是早期结果不确定度的两倍。我们对Ne的结果与早期结果存在较大偏差,但可能比我们的其他测量受到更大的系统效应影响。分子光谱与我们的含时密度泛函理论结果非常吻合。我们发现统计不确定度允许在1-10 meV的期望范围内进行校准,然而系统贡献仍将不确定度限制在约40-100 meV,这主要归因于单色器能量标度的时间稳定性。将我们的绝对校准技术与光电子能谱等相对能量校准技术相结合,将是实现低至1-10 meV不确定度全部潜力的必要条件。

英文摘要:

A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of Ne, CO$_2$, and SF$_6$ gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s-np fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the CO$_2$ result agrees well with previous measurements, the SF$_6$ spectrum appears shifted by ~0.5 eV, about twice the uncertainty of the earlier results. Our result for Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1-10 meV, however, systematic contributions still limit the uncertainty to ~40-100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1-10 meV.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑