银河宇宙射线对神经元损伤的纳米尺度模拟

Nano-scale simulation of neuronal damage by galactic cosmic rays

Jonah S. Peter, Jan Schuemann, Kathryn D. Held, Aimee L. McNamara

摘要:

复杂的混合离子辐射场对神经元功能的影响在很大程度上尚未探索。在这里,我们提出了一个完整的分析与宽光谱银河宇宙射线(GCR)照射在一个现实的角ammonis 1(CA 1)锥体神经元几何的纳米尺度物理。我们模拟了目前在美国宇航局空间辐射实验室银河宇宙射线模拟器(GCRSim)使用的整个33离子能量束流密度分布。我们使用TOol的PArticle模拟(TOPAS)和TOPAS-nBio蒙特卡洛为基础的轨道结构模拟工具包,以评估在纳米尺度上的剂量学,物理过程,和不同的神经元隔间的注量统计。我们还比较了完整的GCRSim分布和简化的6离子能谱(SimGCRSim)。我们发现,在所有的物理过程中,电离介导的能量沉积$(68 \pm 1\%)$的大部分,虽然振动激发是最丰富的(所有能量沉积事件的$70 \pm 2\%$)。我们报告说,神经元的能量沉积质子和$α$粒子轨道下降约双曲线增加初级粒子能量在任务相关的能量。我们还证明了树突段照射概率和神经元吸收剂量之间的倒指数关系。最后,我们发现,有没有显着差异的平均物理响应之间的GCRSim和SimGCRSim注量分布。据我们所知,这是第一个使用GCRSim和SimGCRSim注量分布对现实神经元几何形状进行的纳米级模拟研究。这里提出的结果有望有助于解释未来的实验结果,并帮助指导未来的研究设计。

英文摘要:

The effects of complex, mixed-ion radiation fields on neuronal function remain largely unexplored. Here, we present a complete analysis of the nano-scale physics associated with broad-spectrum galactic cosmic ray (GCR) irradiation in a realistic cornu ammonis 1 (CA1) pyramidal neuron geometry. We simulate the entire 33 ion-energy beam fluence distribution currently in use at the NASA Space Radiation Laboratory galactic cosmic ray simulator (GCRSim). We use the TOol for PArticle Simulation (TOPAS) and TOPAS-nBio Monte Carlo-based track structure simulation toolkits to assess the dosimetry, physics processes, and fluence statistics of different neuronal compartments at the nanometer scale. We also make comparisons between the full GCRSim distribution and a simplified 6 ion-energy spectrum (SimGCRSim). We show that across all physics processes, ionizations mediate the majority of the energy deposition $(68 \pm 1\%)$, though vibrational excitations are the most abundant ($70 \pm 2\%$ of all energy deposition events). We report that neuronal energy deposition by proton and $α$-particle tracks declines approximately hyperbolically with increasing primary particle energy at mission-relevant energies. We also demonstrate an inverted exponential relationship between dendritic segment irradiation probability and neuronal absorbed dose. Finally, we find that there are no significant differences in the average physical responses between the GCRSim and SimGCRSim fluence distributions. To our knowledge, this is the first nano-scale simulation study of a realistic neuron geometry using the GCRSim and SimGCRSim fluence distributions. The results presented here are expected to aid in the interpretation of future experimental results and help guide future study designs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑