arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2202.00650physics.med-phcs.CV
收藏

基于人工智能的医疗电子诊断快速自动测量正常压力脑积水患者的心室容积

AI-based Medical e-Diagnosis for Fast and Automatic Ventricular Volume Measurement in the Patients with Normal Pressure Hydrocephalus

The First Affiliated Hospital of Shenzhen University(深圳大学第一附属医院);Shenzhen Second People's Hospital(深圳市第二人民医院);University of California, San Diego(加州大学圣地亚哥分校);University of the Basque Country (UPV/EHU)(巴斯克大学);Royal Brompton Hospital(皇家布朗普顿医院);National Heart and Lung Institute, Imperial College London(帝国理工学院国立心肺研究所)

Xi Zhou, Qinghao Ye, Xiaolin Yang, Jiakuan Chen, Haiqin Ma, Jun Xia, Javier Del Ser, Guang Yang

摘要:

基于正常压力脑积水(normal pressure hydrocephalus,NPH)患者的CT和MRI图像,利用机器学习方法,建立一种多模态、高性能的脑室自动分割方法,实现高效、准确的脑室容积自动测量。首先,我们提取了143例确诊的NPH患者的脑CT和MRI图像。其次,我们手动标记脑室容积(VV)和颅内容积(ICV)。然后,使用机器学习方法提取特征并建立自动心室分割模型。最后,验证了模型的可靠性,实现了VV和ICV的自动测量。在CT图像中,VV的自动和手动分割结果的Dice相似系数(DSC)、类内相关系数(ICC)、Pearson相关性和Bland-Altman分析分别为0.95、0.99、0.99和4.2 $\pm$ 2.6。ICV的结果分别为0.96、0.99、0.99和6.0 $\pm$ 3.8。整个过程需要3.4 $\pm$ 0.3秒。在MRI图像中,VV的自动和手动分割结果的DSC、ICC、Pearson相关性和Bland-Altman分析分别为0.94、0.99、0.99和2.0 $\pm$ 0.6。ICV的结果分别为0.93、0.99、0.99和7.9 $\pm$ 3.8。整个过程耗时1.9 $\pm$ 0.1秒。我们建立了一种多模态、高性能的心室自动分割方法,实现了NPH患者心室容积的高效、准确的自动测量。这可以帮助临床医生快速准确地了解NPH患者的心室情况。

英文摘要:

Based on CT and MRI images acquired from normal pressure hydrocephalus (NPH) patients, using machine learning methods, we aim to establish a multi-modal and high-performance automatic ventricle segmentation method to achieve efficient and accurate automatic measurement of the ventricular volume. First, we extract the brain CT and MRI images of 143 definite NPH patients. Second, we manually label the ventricular volume (VV) and intracranial volume (ICV). Then, we use machine learning method to extract features and establish automatic ventricle segmentation model. Finally, we verify the reliability of the model and achieved automatic measurement of VV and ICV. In CT images, the Dice similarity coefficient (DSC), Intraclass Correlation Coefficient (ICC), Pearson correlation, and Bland-Altman analysis of the automatic and manual segmentation result of the VV were 0.95, 0.99, 0.99, and 4.2$\pm$2.6 respectively. The results of ICV were 0.96, 0.99, 0.99, and 6.0$\pm$3.8 respectively. The whole process takes 3.4$\pm$0.3 seconds. In MRI images, the DSC, ICC, Pearson correlation, and Bland-Altman analysis of the automatic and manual segmentation result of the VV were 0.94, 0.99, 0.99, and 2.0$\pm$0.6 respectively. The results of ICV were 0.93, 0.99, 0.99, and 7.9$\pm$3.8 respectively. The whole process took 1.9$\pm$0.1 seconds. We have established a multi-modal and high-performance automatic ventricle segmentation method to achieve efficient and accurate automatic measurement of the ventricular volume of NPH patients. This can help clinicians quickly and accurately understand the situation of NPH patient's ventricles.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑