arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2201.13191eess.IVphysics.med-ph
收藏

基于快速蒙特卡罗光子输运模型的高分辨率平板CT散射校正

Computational Scatter Correction for High-Resolution Flat-Panel CT Based on a Fast Monte Carlo Photon Transport Model

Ammar Alsaffar, Steffen Kieß, Kaicong Sun, Sven Simon

摘要:

在计算机断层扫描(CT)重建中,散射通过引入条纹和杯状伪影而导致重建CT图像的质量严重下降,这降低了低对比度物体的可检测性。蒙特卡罗(MC)模拟被认为是散射估计的最准确的方法。然而,现有的MC估计是计算昂贵的,特别是对于所考虑的高分辨率平板CT。在本文中,我们提出了一个快速,准确的光子输运模型,它描述了1 keV至1 MeV范围内的物理使用多个可控的关键参数。基于该模型,在定义好的模型参数下,单个投影的散射计算可以在几秒的范围内完成。对估计的散射进行平滑和插值,以加速散射计算,而不会与测量的近无散射投影图像相比过多地损害准确性。将散射估计与滤波反投影(FBP)相结合,以迭代方式有效地执行散射校正。为了评估所提出的MC模型,我们进行了广泛的实验模拟数据和现实世界的高分辨率平板CT。与最先进的MC模拟器相比,我们的光子输运模型在四GPU系统上实现了202 $\times$的加速,与多线程的最先进的EGSnrc MC模拟器相比。此外,它示出,对于现实世界的高分辨率平板CT,散射校正具有足够的精度是在一到三次迭代内完成使用的FBP和前向投影计算与建议的快速MC光子传输模型。

英文摘要:

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC) simulation is considered as the most accurate approach for scatter estimation. However, the existing MC estimators are computationally expensive especially for the considered high-resolution flat-panel CT. In this paper, we propose a fast and accurate photon transport model which describes the physics within the 1 keV to 1 MeV range using multiple controllable key parameters. Based on this model, scatter computation for a single projection can be completed within a range of few seconds under well-defined model parameters. Smoothing and interpolation are performed on the estimated scatter to accelerate the scatter calculation without compromising accuracy too much compared to measured near scatter-free projection images. Combining the scatter estimation with the filtered backprojection (FBP), scatter correction is performed effectively in an iterative manner. In order to evaluate the proposed MC model, we have conducted extensive experiments on the simulated data and real-world high-resolution flat-panel CT. Comparing to the state-of-the-art MC simulators, our photon transport model achieved a 202$\times$ speed-up on a four GPU system comparing to the multi-threaded state-of-the-art EGSnrc MC simulator. Besides, it is shown that for real-world high-resolution flat-panel CT, scatter correction with sufficient accuracy is accomplished within one to three iterations using a FBP and a forward projection computed with the proposed fast MC photon transport model.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑