arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2112.03441physics.bio-phphysics.chem-ph
收藏

使用TD-DFT对EGFR抑制剂AG-1478的吸收和荧光光谱的DFT官能团的性能进行基准测试

Benchmarking the performance of DFT functionals for absorption and fluorescence spectra of EGFR inhibitor AG-1478 using TD-DFT

Sallam Alagawani, Vladislav Vasilyev, Feng Wang

摘要:

光学光谱(紫外-可见和荧光)对荧光团的化学环境和构象敏感,因此是其构象和溶剂响应的理想探针。酪氨酸激酶抑制剂(TKI)如表皮生长因子受体(EGFR)的AG-1478当含有喹唑啉胺支架时是荧光团。AG-1478的构象已被实验和理论证实。然而,当应用含时密度泛函理论(TD-DFT)研究荧光团时,对DFT泛函等计算方法与光谱测量进行基准测试是非常重要的。在这项研究中,多达22个DFT功能的性能基准相对于测量的光谱AG-1478在二甲基亚砜(DMSO)溶剂。与6-311++G(d,p)基组相结合,发现B3 PW 91,B3 LYP,B3 P86,BPE 1BPE,APFD,HSEH 1 PBE,N12 SX DFT-VXC泛函表现最好.与其他交换泛函相比,Beckes三参数交换泛函(B3)倾向于产生准确的光谱。B3 PW 91泛函是这类TKI的光学性质计算的推荐DFT泛函,而B3 LYP对于吸收计算是极好的,B3 P86对于发射计算是最好的。对B3 LYP的任何校正,如CAM-B3 LYP、LC-B3 LYP和B3 LYP-D3,都会导致AG-1478在DMSO溶剂中的光谱出现较大误差。这些B3 Vc泛函是用于TKI的光学性质的可靠工具,因此是用于医学图像应用的具有较大斯托克斯位移的新试剂的设计的可靠工具。

英文摘要:

Optical spectra (UV-vis and fluorescence) are sensitive to the chemical environment and conformation of fluorophores and therefore, are ideal probes for their conformation and solvent responses. Tyrosine kinase inhibitors (TKI) such as AG-1478 of epidermal growth factor receptor (EGFR) when containing a quinazolinamine scaffold are fluorophores. Conformers of AG-1478 have been confirmed by both experiment and theory. It is, however, very important to benchmark computational methods such as DFT functionals against optical spectral measurements, when time-dependent density functional theory (TD-DFT) is applied to study the fluorophores. In this study, the performance of up to 22 DFT functionals is benchmarked with respect to the measured optical spectra of AG-1478 in dimethyl sulfoxide (DMSO) solvent. It is discovered when combined with the 6-311++G(d,p) basis set, B3PW91, B3LYP, B3P86, BPE1BPE, APFD, HSEH1PBE, and N12SX DFT-VXC functionals are the top performers. Beckes three-parameter exchange functional (B3) tends to generate accurate optical spectra over other exchange functionals. The B3PW91 functional is the recommended DFT functional for optical property calculations of this class of TKIs whereas B3LYP is excellent for absorption calculations and B3P86 is best for emission calculations. Any corrections to B3LYP, such as CAM-B3LYP, LC-B3LYP, and B3LYP-D3 result in larger errors in the optical spectra of AG-1478 in DMSO solvent. These B3Vc functionals are reliable tools for optical properties of the TKIs and therefore the design of new agents with larger Stokes shift for medical image applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑