亚毫米波高斯光束照射下球薄壳中纵模的耦合:在角膜传感中的应用

Coupling to longitudinal modes in spherical thin shells illuminated by submillimeter wave Gaussian beam: applications to corneal sensing

Faezeh Zarrinkhat, Joel Lamberg, Aleksi Tamminen, Mariangela Baggio, Juha Ala-Laurinaho, Elsayed E. M. Khaled, Juan Rius, Jordi Romeu, Zachary Taylor

摘要:

采用基于傅里叶光学分析和矢量球谐函数的理论方法,研究了高斯光束照射下薄球壳的纵模耦合问题。照明频带固定在100-600 GHz之间,并且外球面壳的曲率半径曲率半径和厚度分别为7.5 mm和0.5 mm。壳体材料是无损角膜或代表角膜的水性有效介质。六种不同的波束目标的战略被引入的潜在候选人最大耦合。采用固定入射光束1/e半径和曲率半径的前向策略,建立了两个相位中心位置与频率密切相关的色散调谐光束系综。这些计算的不同的路线继续与四个光束系综的频率不变的相位中心,构建从拟合到实验数据,定向在四个不同的轴向位置相对于球壳的曲率曲率中心,他们被称为反向策略。针对不同的靶标计算所有策略的耦合效率,所述靶标包括PEC球、空气芯和被角膜无损失层和角膜覆盖的PEC芯。所有的散射策略与等效平面目标的散射进行对比,作为具有最大耦合的参考。结果表明,在理想的校准下,前向策略更接近于平面波条件。然而,目标特性显著地影响耦合效率,例如,由于介电损耗限制了走离损耗,所以在角膜散射中观察到的差异非常小。此外,在扰动校准下,前向策略表现出较低的灵敏度。

英文摘要:

Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics. The illumination frequency band was fixed between 100-600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including PEC sphere, air-core, and PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition. However, target properties influence the coupling efficiency remarkably for instance the observed difference in cornea scattering is vanishingly small as dielectric loss limits walk-off loss. Furthermore, under perturbed calibration, the forward strategies showed less sensitivity.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑