arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2111.14925astro-ph.HEastro-ph.GA
收藏

用贝叶斯方法重建AGN X射线谱参数分布I:谱分析

Reconstructing AGN X-ray spectral parameter distributions with Bayesian methods I: Spectral analysis

Lingsong Ge, Stéphane Paltani, Dominique Eckert

摘要:

活动星系核(AGN)的X射线谱由几种不同的发射和吸收成分组成,通常需要根据具体情况选择模型进行人工拟合。然而,对于具有大量源的调查来说,这变得非常困难。此外,当信噪比(S/N)较低时,有一种倾向,即采用过于简单的模型,使参数产生偏差,并使其不确定性不切实际。我们开发了一种贝叶斯方法自动拟合XMM牛顿活动星系核X射线光谱与一致的和物理动机的模型,包括所有的光谱成分,即使数据质量低。经验模型用于非X射线背景。对光子指数(Gamma)和氢柱密度(N_H)应用无信息先验,而从深层调查获得的信息先验用于边缘化其余参数。我们测试了这种方法使用一个逼真的模拟样本的5000光谱再现典型的人口属性。光谱参数是从先验随机抽取的,同时考虑到光度函数。在低信噪比条件下,对N_H、Gamma和L_X等参数得到了有意义的后验概率密度分布,但在这种情况下,我们无法约束反射和软过剩等二次分量的参数。作为比较,一个最大似然方法与模型选择之间的六个模型的不同复杂性也适用于这个样本。我们发现,在大多数情况下,γ的测量明显失败,当源未被吸收时(NH < 10^22 cm-2),NH的测量也失败。结果很难被用来重建的光谱参数的父分布,而我们的贝叶斯方法提供了有意义的多维后验,将在随后的论文中使用,以推断人口。(节略)

英文摘要:

X-ray spectra of active galactic nuclei (AGN) consist of several different emission and absorption components, which are often fitted manually with models chosen on a case-by-case basis. However, it becomes very hard for a survey with a large number of sources. In addition, when the signal-to-noise ratio (S/N) is low, there is a tendency to adopt an overly simplistic model, biasing the parameters and making their uncertainties unrealistic. We developed a Bayesian method for automatically fitting XMM-Newton AGN X-ray spectra with a consistent and physically motivated model including all spectral components, even when the data quality is low. An empirical model is used for the non-X-ray background. Noninformative priors were applied on the photon index (Gamma) and the hydrogen column density (N_H), while informative priors obtained from deep surveys were used to marginalize the remaining parameters. We tested this method using a realistically simulated sample of 5000 spectra reproducing typical population properties. Spectral parameters were randomly drawn from the priors, taking the luminosity function into account. Meaningful posterior probability density distributions were obtained for, for instance, N_H, Gamma, and L_X, even at low S/N, but in this case, we were unable to constrain the parameters of secondary components such as the reflection and soft excess. As a comparison, a maximum-likelihood approach with model selection among six models of different complexities was also applied to this sample. We find clear failures in the measurement of Gamma in most cases, and of N_H when the source is unabsorbed (N_H < 10^22 cm-2). The results can hardly be used to reconstruct the parent distributions of the spectral parameters, while our Bayesian method provides meaningful multidimensional posteriors that will be used in a subsequent paper to infer the population. (abridged)

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑