arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2111.12192physics.chem-ph
收藏

Polymer吸收到圆柱形纳米孔阵列中的亚微米X射线断层扫描数据的统计分析

Statistical Analysis of Submicron X-Ray Tomography Data on Polymer Imbibition into Arrays of Cylindrical Nanopores

Fernando Vazquez Luna, Michael Gerstenberger, Guido Dittrich, Juliana Martins de Souza e Silva, Patrick Huber, Ralf Wehrspohn, Martin Steinhart

摘要:

利用相位衬度X射线计算机断层成像对直径为400 nm的直圆柱孔阵列中的冻结瞬态吸胀状态进行了成像,具有单孔分辨率。描述了一种半自动算法,该算法产生沿探测样品体积内确定的所有孔的亮度曲线。吸胀前沿位置由描述性统计确定。第一种方法涉及的频率密度的单孔吸液长度的评价,第二个的评价的统计亮度分散内的探测体积作为一个函数的距离,从孔嘴。我们绘制了平均吸胀前的位置对系统的不同权力的吸胀时间,并确定了最佳指数的吸胀时间考虑相应的线性拟合的相关系数。因此,从平均吸胀前沿位置的比例,由卢卡斯-沃什伯恩理论预测的吸胀时间的平方根的微小偏差被发现。一个有意义的指数前因子的幂律吸胀前沿位置和吸胀时间的关系,可以只确定后,关于吸胀时间的指数的模糊性被解决。分散的峰值代表的吸胀前的频率密度的单孔吸胀长度和亮度分散曲线绘制对孔深度的建议作为测量的吸胀前的宽度。相位衬度X射线计算机断层成像允许利用相位衬度成像来评估大量渗透的亚微米孔隙;避免了与需要物理消融样品材料的断层成像造成的样品损坏相关的伪影。

英文摘要:

Frozen transient imbibition states in arrays of straight cylindrical pores 400 nm in diameter were imaged by phase-contrast X-ray computed tomography with single-pore resolution. A semi-automatic algorithm yielding brightness profiles along all pores identified within the probed sample volume is described. Imbibition front positions are determined by descriptive statistics. A first approach involves the evaluation of frequency densities of single-pore imbibition lengths, a second one the evaluation of the statistical brightness dispersion within the probed volume as a function of the distance from the pore mouths. We plotted average imbibition front positions against systematically varied powers of the imbibition time and determined the optimal exponent of the imbibition time by considering the correlation coefficients of the corresponding linear fits. Thus, slight deviations from the proportionality of the average imbibition front position to the square root of the imbibition time predicted by the Lucas-Washburn theory were found. A meaningful preexponential factor in the power law relating imbibition front position and imbibition time may only be determined after ambiguities regarding the exponent of the imbibition time are resolved. The dispersion of peaks representing the imbibition front in frequency densities of single-pore imbibition lengths and in brightness dispersion profiles plotted against the pore depth is suggested as measure of the imbibition front width. Phase-contrast X-ray computed tomography allows the evaluation of a large number of infiltrated submicron pores taking advantage of phase-contrast imaging; artifacts related to sample damage by tomography requiring physical ablation of sample material are avoided.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑