技术注释:使用其他Monte Carlo代码和相空间文件实现的MC-GPU乳房剂量测定确认
Technical Note: MC-GPU breast dosimetry validations with other Monte Carlo codes and Phase Space File implementation
摘要:
目的:确认MC-GPU蒙特卡罗代码用于X射线乳腺成像模式中的剂量测定研究:乳腺X射线摄影、数字乳腺断层合成摄影、对比度增强数字乳腺X射线摄影和乳腺CT。此外,实现并验证了一个相空间文件生成程序。研究方法:修改了MC-GPU代码(v. 1.5 DBT),以生成相空间文件,并与PENTHAL PE v. 2018导出的截面数据库兼容。模拟进行了同质和拟人乳房假体不同的乳房成像技术。计算每种情况下的腺体剂量,并与PENDIX PE(v. 2014)+ penEasy(v. 2015)和egs brachy(EGSnrc)Monte Carlo代码的结果进行比较。然后,用MC-GPU生成多个相空间文件,并比较代码之间的评分光子谱。结果如下:MC-GPU在计算乳腺X射线摄影的腺体剂量分布、数字乳腺断层合成的平均腺体剂量和乳腺CT的归一化腺体剂量时,与其他代码表现出良好的一致性。后一种情况下,平均/最大相对差异分别为2.3%/27%,与其他文献作品相比,在低能量(约10 keV)下观察到的差异较大。记录的光子光谱进入一个体素之间的三个蒙特卡罗代码是相似的(统计不确定性)。结论:结果表明,MC-GPU代码适用于不同X射线乳腺成像模式的乳腺剂量学研究,具有高性能的优势。相空间文件的实现是经过验证的,并且与IAEA标准兼容,允许使用CPU和GPU代码的组合进行多尺度蒙特卡罗模拟。
英文摘要:
Purpose: To validate the MC-GPU Monte Carlo code for dosimetric studies in x-ray breast imaging modalities: mammography, digital breast tomosynthesis, contrast enhanced digital mammography and breast-CT. Moreover, to implement and validate a phase space file generation routine. Methods: The MC-GPU code (v. 1.5 DBT) was modified in order to generate phase space files and to be compatible with PENELOPE v. 2018 derived cross section database. Simulations were performed with homogeneous and anthropomorphic breast phantoms for different breast imaging techniques. The glandular dose was computed for each case and compared with results from the PENELOPE (v. 2014) + penEasy (v. 2015) and egs brachy (EGSnrc) Monte Carlo codes. Afterwards, several phase space files were generated with MC-GPU and the scored photon spectra were compared between the codes. Results: MC-GPU showed good agreement with the other codes when calculating the glandular dose distribution for mammography, mean glandular dose for digital breast tomosynthesis, and normalized glandular dose for breast-CT. The latter case showed average/maximum relative differences of 2.3%/27%, respectively, compared to other literature works, with the larger differences observed at low energies (around 10 keV). The recorded photon spectra entering a voxel were similar (within statistical uncertainties) between the three Monte Carlo codes. Conclusions: The results indicate that MC-GPU code is suitable for breast dosimetric studies for different x-ray breast imaging modalities, with the advantage of a high performance. The phase space file implementation was validated and is compatible with the IAEA standard, allowing multiscale Monte Carlo simulations with a combination of CPU and GPU codes.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。