使用常规几何同步加速器辅助的EDXRF测量在十亿分之一范围内标记元素检测灵敏度
Labeling elemental detection sensitivities in part per billion range using conventional geometry synchrotron assisted EDXRF measurements
摘要:
能量色散X射线荧光(EDXRF)是一种广泛应用于材料中微量和痕量多元素分析的非破坏性技术。常规试验表明,使用实验室辅助的EDXRF测量,可以获得μg/g至亚μg/g水平范围内的元素检测限。在本工作中,定量的方法已被遵循,试图探索如何可能获得的元素检测限的范围内的ng/g,通过使用简单的EDXRF激发(45°- 45°几何),而不是使用全反射X射线荧光(TXRF)技术,使相对优越的检测限不同的元素。为了实现这一点,我们在类似的实验条件下记录了标准参考样品(ICP-IV)的荧光光谱。结果表明,在25-50 μm厚的Kapton薄膜上放置少量样品,EDXRF技术可提供与TXRF技术相当的元素检出限。
英文摘要:
Energy dispersive X-ray fluorescence (EDXRF) is a widely used non-destructive technique for micro and trace multi-element analysis of materials. Conventional trials show that using laboratory assisted EDXRF measurements, one can obtain elemental detection limits in the range of μg/g to sub-μg/g level. In the present work a quantitative approach has been followed in attempting to explore how is it possible to obtain elemental detection limit in the range of ng/g by using simple EDXRF excitation (45°- 45° geometry) instead of using total reflection X-ray fluorescence (TXRF) technique, which renders relatively superior detection limits for different elements. In order to accomplish this, we recorded fluorescence spectrum from a standard reference sample (ICP-IV) in similar experimental conditions. The results show that using a very small quantity of sample on top of a thin kapton foil with a thickness ranging between 25-50 μm, as a sample carrier, the EDXRF technique may offer comparable elemental detection limits in contrast to TXRF technique.