中国-西班牙联合开展COVID-19眼部快速风险筛查临床试验报告
The Report on China-Spain Joint Clinical Testing for Rapid COVID-19 Risk Screening by Eye-region Manifestations
摘要:
背景:全球冠状病毒病例激增导致COVID-19检测需求激增。全球迫切需要在人群水平上进行快速、准确和具有成本效益的COVID-19筛查测试。研究方法:基于COVID-19的眼部症状,我们使用手机摄像头在中国和西班牙拍摄的眼区图像开发并测试了COVID-19快速预筛选模型。基于卷积神经网络(CNN)的模型在这些眼睛图像上进行训练,以完成识别COVID-19病例的二进制分类任务。使用受试者工作特征曲线下面积(AUC)、灵敏度、特异性、准确性和F1来测量性能。应用程序编程接口是开放访问的。调查结果:该多中心研究包括开发数据集(训练和验证)中对应于657例受试者(155例COVID-19感染,23.6%)的2436张图片和测试数据集中对应于478例受试者(64例COVID-19感染,13.4%)的2138张图片。在中国-西班牙多中心研究中,COVID-19预筛选模型的图像级性能达到AUC 0.913(95% CI,0.898-0.927),灵敏度为0.695(95%CI,0.643-0.748),特异性为0.904(95%CI,0.891 - 0.919),准确性为0.875(0.861-0.889),F1为0.611(0.568-0.655)。解读:基于CNN的COVID-19快速预筛查模型具有可靠的特异性和灵敏度。该系统为COVID-19的持续监测和大规模快速预筛查提供了低成本、完全自我执行、非侵入性、实时反馈的解决方案。资助:本项目由Aimomics(上海)智能
英文摘要:
Background: The worldwide surge in coronavirus cases has led to the COVID-19 testing demand surge. Rapid, accurate, and cost-effective COVID-19 screening tests working at a population level are in imperative demand globally. Methods: Based on the eye symptoms of COVID-19, we developed and tested a COVID-19 rapid prescreening model using the eye-region images captured in China and Spain with cellphone cameras. The convolutional neural networks (CNNs)-based model was trained on these eye images to complete binary classification task of identifying the COVID-19 cases. The performance was measured using area under receiver-operating-characteristic curve (AUC), sensitivity, specificity, accuracy, and F1. The application programming interface was open access. Findings: The multicenter study included 2436 pictures corresponding to 657 subjects (155 COVID-19 infection, 23.6%) in development dataset (train and validation) and 2138 pictures corresponding to 478 subjects (64 COVID-19 infections, 13.4%) in test dataset. The image-level performance of COVID-19 prescreening model in the China-Spain multicenter study achieved an AUC of 0.913 (95% CI, 0.898-0.927), with a sensitivity of 0.695 (95% CI, 0.643-0.748), a specificity of 0.904 (95% CI, 0.891 -0.919), an accuracy of 0.875(0.861-0.889), and a F1 of 0.611(0.568-0.655). Interpretation: The CNN-based model for COVID-19 rapid prescreening has reliable specificity and sensitivity. This system provides a low-cost, fully self-performed, non-invasive, real-time feedback solution for continuous surveillance and large-scale rapid prescreening for COVID-19. Funding: This project is supported by Aimomics (Shanghai) Intelligent
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。