arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2109.04194cs.HCeess.SP
收藏

采用增量学习方法的新型时域上肢假肢控制

Novel Time Domain Based Upper-Limb Prosthesis Control using Incremental Learning Approach

Sidharth Pancholi, Amit M. Joshi Deepak Joshi, Bradly S. Duerstock

AI总结:

针对传统EMG-PR假肢难以适应电极与手臂位置变化的问题,提出在线增量学习时域控制系统,并在健全者与截肢者上验证了多动作分类性能。

摘要:

上肢对人类的各种活动至关重要。上肢的完全或部分丧失会对截肢者的日常活动造成重大影响。EMG携带有关人体生理状态的重要信息,有助于解码人类手臂的各种功能。过去十年中,基于EMG信号的仿生学与假肢研究受到广泛关注。传统的基于EMG-PR的假肢由于采用离线训练,并且无法补偿电极位置偏移和手臂位置变化,因此难以提供准确性能。本研究提出了一种用于上肢假肢应用的、基于在线训练和增量学习的系统。该系统采用ADS1298作为AFE(模拟前端),并使用32位Arm Cortex-M4处理器进行DSP(数字信号处理)。系统已在健全受试者和截肢受试者身上进行测试。研究实现并使用了基于时间导数矩的特征,以实现有效的模式分类。系统最初通过在线训练流程针对四个类别进行训练,随后根据用户需求将类别数量逐步增加至十一个,并评估系统性能。当考虑四种动作时,系统对健康受试者和截肢受试者均取得100%的完成率。此外,当类别数量增加到十一个时,系统对健康受试者和截肢者分别展现出94.33%和92%的完成率。研究还对所有受试者评估了动作效能测试。健全受试者和截肢受试者分别观察到91.23%和88.64%的最高效能率。

英文摘要:

The upper limb of the body is a vital for various kind of activities for human. The complete or partial loss of the upper limb would lead to a significant impact on daily activities of the amputees. EMG carries important information of human physique which helps to decode the various functionalities of human arm. EMG signal based bionics and prosthesis have gained huge research attention over the past decade. Conventional EMG-PR based prosthesis struggles to give accurate performance due to off-line training used and incapability to compensate for electrode position shift and change in arm position. This work proposes online training and incremental learning based system for upper limb prosthetic application. This system consists of ADS1298 as AFE (analog front end) and a 32 bit arm cortex-m4 processor for DSP (digital signal processing). The system has been tested for both intact and amputated subjects. Time derivative moment based features have been implemented and utilized for effective pattern classification. Initially, system have been trained for four classes using the on-line training process later on the number of classes have been incremented on user demand till eleven, and system performance has been evaluated. The system yielded a completion rate of 100% for healthy and amputated subjects when four motions have been considered. Further 94.33% and 92% completion rate have been showcased by the system when the number of classes increased to eleven for healthy and amputees respectively. The motion efficacy test is also evaluated for all the subjects. The highest efficacy rate of 91.23% and 88.64% are observed for intact and amputated subjects respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑