一种用于瘢痕相关室性心动过速诱导和治疗的自动化近实时计算方法
An automated near-real time computational method for induction and treatment of scar-related ventricular tachycardias
摘要:
导管消融术是目前唯一的治愈性治疗疤痕相关的室性心动过速(VT)。然而,不仅消融手术时间长,风险相对较高,而且成功率极低,室性心动过速复发频繁。个性化的计算机模拟方法有机会解决这些限制。然而,用于计算机模拟消融靶点识别的VT诱导和后续电路的最新反应扩散(R-D)模拟需要较长的执行时间以及大量的计算资源,这与临床工作流程不兼容。在这里,我们提出了虚拟诱导和治疗心律失常(VITA),一种新型的,快速的,全自动的计算方法,使用反应Eikonal方法来诱导室性心动过速,并确定随后的消融目标。VITA的基本原理是基于发现与激动波前相关的等值面,该波前由于瘢痕内存在孤立的传导峡部而在心室中分裂;一旦识别,可以评估每个峡部维持折返回路的脆弱性,并自动识别相应的出口部位以进行潜在的消融靶向。VITA在7个梗死后猪心的虚拟队列上进行了测试,并将结果与R-D模拟进行了比较。仅使用一台标准台式机,VITA就可以检测到所有与疤痕相关的室性心动过速,模拟激活时间图和ECG(用于临床比较),并在48分钟内计算消融目标。通过R-D模拟探测的可比VT在256个高性能计算基础设施核心上花费了68.5小时。由VITA计算的一组病变显示出使心室模型VT自由。VITA可作为辅助梗死后VT治疗的临床决策的补充模式,以接近实时的方式使用。
英文摘要:
Catheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations. However, state-of-the-art reaction diffusion (R-D) simulations of VT induction and subsequent circuits used for in-silico ablation target identification require long execution times, along with vast computational resources, which are incompatible with the clinical workflow. Here, we present the Virtual Induction and Treatment of Arrhythmias (VITA), a novel, rapid and fully automated computational approach that uses reaction-Eikonal methodology to induce VT and identify subsequent ablation targets. The rationale for VITA is based on finding isosurfaces associated with an activation wavefront that splits in the ventricles due to the presence of an isolated isthmus of conduction within the scar; once identified, each isthmus may be assessed for their vulnerability to sustain a reentrant circuit, and the corresponding exit site automatically identified for potential ablation targeting. VITA was tested on a virtual cohort of 7 post-infarcted porcine hearts and the results compared to R-D simulations. Using only a standard desktop machine, VITA could detect all scar-related VTs, simulating activation time maps and ECGs (for clinical comparison) as well as computing ablation targets in 48 minutes. The comparable VTs probed by the R-D simulations took 68.5 hours on 256 cores of high-performance computing infrastructure. The set of lesions computed by VITA was shown to render the ventricular model VT-free. VITA could be used in near real-time as a complementary modality aiding in clinical decision-making in the treatment of post-infarction VTs.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。