基于系统矩阵的脉冲序列磁粒子成像重建

System Matrix based Reconstruction for Pulsed Sequences in Magnetic Particle Imaging

Fabian Mohn, Tobias Knopp, Marija Boberg, Florian Thieben, Patryk Szwargulski, Matthias Graeser

摘要:

提高分辨率和灵敏度将拓宽磁粒子成像的可能医学应用。脉冲激励承诺这样的好处,在更复杂的硬件解决方案和驱动场振幅和频率的限制的成本。最先进的系统利用正弦激励来驱动超顺磁性纳米颗粒进入其磁化曲线的非线性部分,这产生了具有直接馈通和由颗粒响应引起的高次谐波的清晰分离的光谱。矩形激励的一个挑战是粒子和激励信号的鉴别,两者都是宽带的。另一个原因是驱动场序列本身,因为没有放置在相同空间位置的粒子可以同时反应,并且不能通过它们的信号相位或形状分离。为了克服这种潜在的信息丢失在空间编码高振幅,位移场和驱动场旋转的叠加提出了这项工作。在近距离观察时,如果对脉冲序列的响应仍然对相位内的信息进行编码,则系统矩阵方法能够独立于序列而保持分辨率。测量和校准任意波形磁粒子谱仪的数据,在两个空间维度上的偏移,以保证设备的独立性。多个序列类型和波形进行比较,基于频率空间图像重建从仿真信号,这是从测量的粒子响应。在x和y方向上的分辨率为1.0 mT(梯度为(-1.25,\,1,2.5,\,2.5)T/m时为0.8 mm),并在参考体模的基础上检测到脉冲序列的优越灵敏度。

英文摘要:

Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude and frequency. State-of-the-art systems utilize a sinusoidal excitation to drive superparamagnetic nanoparticles into the non-linear part of their magnetization curve, which creates a spectrum with a clear separation of direct feed-through and higher harmonics caused by the particles response. One challenge for rectangular excitation is the discrimination of particle and excitation signals, both broad-band. Another is the drive-field sequence itself, as particles that are not placed at the same spatial position, may react simultaneously and are not separable by their signal phase or shape. To overcome this potential loss of information in spatial encoding for high amplitudes, a superposition of shifting fields and drive-field rotations is proposed in this work. Upon close view, a system matrix approach is capable to maintain resolution, independent of the sequence, if the response to pulsed sequences still encodes information within the phase. Data from an Arbitrary Waveform Magnetic Particle Spectrometer with offsets in two spatial dimensions is measured and calibrated to guarantee device independence. Multiple sequence types and waveforms are compared, based on frequency space image reconstruction from emulated signals, that are derived from measured particle responses. A resolution of 1.0 mT (0.8 mm for a gradient of (-1.25,\,-1.25,\,2.5) T/m) in x- and y-direction was achieved and a superior sensitivity for pulsed sequences was detected on the basis of reference phantoms.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑