arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2108.08793eess.SPphysics.data-an
收藏

流行的金属氧化物传感器数据集的漂移揭示了气体分类基准的局限性

Drift in a Popular Metal Oxide Sensor Dataset Reveals Limitations for Gas Classification Benchmarks

Nik Dennler, Shavika Rastogi, Jordi Fonollosa, André van Schaik, Michael Schmuker

摘要:

金属氧化物(MOx)电化学气体传感器由于其可调灵敏度、空间效率和低价格而成为许多应用的明智选择。公开可用的传感器数据集简化了新算法和电路设计的开发和评估,使其对人工嗅觉/移动机器人嗅觉社区特别有价值。2013年,Vergara等人发表了一个数据集,其中包括风洞中大型MOx气体传感器阵列16个月的记录,该数据集已成为该领域的标准基准。在这里,我们报告了一个以前未检测到的属性的数据集,限制其适用于气体分类研究。个别测量时间戳的分析表明,气体被记录在时间上集群批次。气体暴露前的传感器响应与记录时间之间的相应相关性通常足以预测给定试验中使用的气体。即使通过零偏移距相减进行补偿,剩余的短期漂移也包含了足够的气体分类信息。我们已经确定了一个受漂移影响最小的数据子集,该数据子集适用于零偏移减法后的气体分类基准测试,尽管气体分类性能大大低于完整数据集。我们的结论是,以前的研究与此数据集很可能高估了气体分类结果的准确性。对于17篇可能受影响的出版物,我们敦促作者根据我们的发现重新评估结果。我们的观察强调需要彻底记录气体传感数据集,并在使用它们开发算法之前进行适当的验证。

英文摘要:

Metal oxide (MOx) electro-chemical gas sensors are a sensible choice for many applications, due to their tunable sensitivity, their space-efficiency and their low price. Publicly available sensor datasets streamline the development and evaluation of novel algorithm and circuit designs, making them particularly valuable for the Artificial Olfaction / Mobile Robot Olfaction community. In 2013, Vergara et al. published a dataset comprising 16 months of recordings from a large MOx gas sensor array in a wind tunnel, which has since become a standard benchmark in the field. Here we report a previously undetected property of the dataset that limits its suitability for gas classification studies. The analysis of individual measurement timestamps reveals that gases were recorded in temporally clustered batches. The consequential correlation between the sensor response before gas exposure and the time of recording is often sufficient to predict the gas used in a given trial. Even if compensated by zero-offset-subtraction, residual short-term drift contains enough information for gas classification. We have identified a minimally drift-affected subset of the data, which is suitable for gas classification benchmarking after zero-offset-subtraction, although gas classification performance was substantially lower than for the full dataset. We conclude that previous studies conducted with this dataset very likely overestimate the accuracy of gas classification results. For the 17 potentially affected publications, we urge the authors to re-evaluate the results in light of our findings. Our observations emphasize the need to thoroughly document gas sensing datasets, and proper validation before using them for the development of algorithms.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑