arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2108.05674astro-ph.IM
收藏

miniJPAS综述:JPAS -{ \it Pathfinder}相机光子响应非均匀性的波长依赖性研究

The miniJPAS Survey: A Study on Wavelength Dependence of the Photon Response Non-uniformity of the JPAS-{\it Pathfinder} Camera

Kai Xiao, Haibo Yuan, J. Varela, Hu Zhan, Jifeng Liu, D. Muniesa, A. Moreno, J. Cenarro, D. Cristóbal-Hornillos, A. Marín-Franch, M. Moles, H. Vázquez-Ramió, C.… 展开作者

Kai Xiao, Haibo Yuan, J. Varela, Hu Zhan, Jifeng Liu, D. Muniesa, A. Moreno, J. Cenarro, D. Cristóbal-Hornillos, A. Marín-Franch, M. Moles, H. Vázquez-Ramió, C. López-Sanjuan, J. Alcaniz, R. Dupke, C. M. de Oliveira, L. Sodré, A. Ederoclite, R. Abramo, N. Benitez, S. Carneiro, K. Taylor, S. Bonoli

摘要:

了解CCD的小尺度平面的起源及其随波长的变化在天文物体的高精度测光,天体测量和形状测量中起着重要的作用。基于JPAS-{ \it Pathfinder}提供的47个窄带滤光片的唯一平坦度数据,分析了小尺度平坦度随波长的变化。我们发现适度的变化(从约$1.0\%$在390 nm到$0.3\%$在890 nm)的小规模单位之间的不同的过滤器,增加向较短的波长。中心波长相近的两个滤波器的小尺度平坦部分具有很强的相关性。然后,我们使用一个简单的物理模型来重现所观察到的变化,约$\pm 0.14\%$的精度,通过考虑电荷收集效率,有效面积和CCD像素之间的厚度的变化。我们发现JPAS-{ \it Pathfinder}相机的小尺度平板的波长依赖性变化源于量子效率(特别是电荷收集效率)以及CCD像素的有效面积和厚度的不均匀性。前者在短波长处占主导地位,而后两者在较长波长处占主导地位。适当的平场以及光度/无狭缝光谱测量的光度/通量校准的影响进行了讨论,特别是在蓝色过滤器/波长。我们还发现,不同的模型参数是敏感的平台,不同的波长,取决于电子吸收深度,光子吸收长度和CCD厚度之间的关系。为了模拟小尺度平坦的波长依赖性变化,少量(约10个)具有精心选择的波长的小尺度平坦足以重建其他波长的小尺度平坦。

英文摘要:

Understanding the origins of small-scale flats of CCDs and their wavelength-dependent variations plays an important role in high-precision photometric, astrometric, and shape measurements of astronomical objects. Based on the unique flat data of 47 narrow-band filters provided by JPAS-{\it Pathfinder}, we analyze the variations of small-scale flats as a function of wavelength. We find moderate variations (from about $1.0\%$ at 390 nm to $0.3\%$ at 890 nm) of small-scale flats among different filters, increasing towards shorter wavelengths. Small-scale flats of two filters close in central wavelengths are strongly correlated. We then use a simple physical model to reproduce the observed variations to a precision of about $\pm 0.14\%$, by considering the variations of charge collection efficiencies, effective areas and thicknesses between CCD pixels. We find that the wavelength-dependent variations of small-scale flats of the JPAS-{\it Pathfinder} camera originate from inhomogeneities of the quantum efficiency (particularly charge collection efficiency) as well as the effective area and thickness of CCD pixels. The former dominates the variations in short wavelengths while the latter two dominate at longer wavelengths. The effects on proper flat-fielding as well as on photometric/flux calibrations for photometric/slit-less spectroscopic surveys are discussed, particularly in blue filters/wavelengths. We also find that different model parameters are sensitive to flats of different wavelengths, depending on the relations between the electron absorption depth, the photon absorption length and the CCD thickness. In order to model the wavelength-dependent variations of small-scale flats, a small number (around ten) of small-scale flats with well-selected wavelengths are sufficient to reconstruct small-scale flats in other wavelengths.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑