arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2108.05616physics.opticseess.IV
收藏

SSR-PR:基于两次先验校准测试的单次超分辨率相位恢复

SSR-PR: Single-shot Super-Resolution Phase Retrieval based two prior calibration tests

Peter Kocsis, Igor Shevkunov, Vladimir Katkovnik, Heikki Rekola, Karen Egiazarian

摘要:

我们提出了一种新的方法和算法的基础上,两个初步的测试的光学系统元件,以提高超分辨复值成像。该方法被开发用于单次拍摄无透镜光学装置中的反相位成像。成像是基于波前调制由一个单一的二元相位掩模。初步测试补偿了光学系统中的误差,并校正了承载波前,缩小了现实生活中的实验和计算建模之间的差距,从而在定性和定量方面显着改善了成像。这两个测试是为了观察激光束和相位掩模,可以被认为是一个初步的系统校准。将校正后的载波波前嵌入到所提出的迭代单次超分辨相位恢复(SSR-PR)算法中。改进的初始衍射图案上采样以及基于稀疏和深度学习的滤波器的组合实现了超分辨率重建。仿真和物理实验证明了高质量的超分辨相位成像。在模拟中,我们表明SSR-PR算法校正了所提出的光学系统的误差,并重建了比传感器像素尺寸小4倍的相位细节。在物理实验中,2um厚的线的美国空军相位目标被解决,这是几乎2倍小于传感器像素大小,并对应于最小的可分辨组使用的测试目标。对于相位生物成像,我们提供了以计算超分辨率重建的颊上皮细胞,其质量与具有40倍放大物镜的数字全息系统相同。此外,单次拍摄的优势提供了记录动态场景的可能性,其中帧率仅受所用相机的限制。我们提供了一个单细胞真核生物的幅相视频剪辑。

英文摘要:

We propose a novel approach and algorithm based on two preliminary tests of the optical system elements to enhance the super-resolved complex-valued imaging. The approach is developed for inverse phase imaging in a single-shot lensless optical setup. Imaging is based on wavefront modulation by a single binary phase mask. The preliminary tests compensate errors in the optical system and correct a carrying wavefront, reducing the gap between real-life experiments and computational modeling, which improve imaging significantly both qualitatively and quantitatively. These two tests are performed for observation of the laser beam and phase mask along, and might be considered as a preliminary system calibration. The corrected carrying wavefront is embedded into the proposed iterative Single-shot Super-Resolution Phase Retrieval (SSR-PR) algorithm. Improved initial diffraction pattern upsampling, and a combination of sparse and deep learning based filters achieves the super-resolved reconstructions. Simulations and physical experiments demonstrate the high-quality super-resolution phase imaging. In the simulations, we showed that the SSR-PR algorithm corrects the errors of the proposed optical system and reconstructs phase details 4x smaller than the sensor pixel size. In physical experiment 2um thick lines of USAF phase-target were resolved, which is almost 2x smaller than the sensor pixel size and corresponds to the smallest resolvable group of used test target. For phase bio-imaging, we provide Buccal Epithelial Cells reconstructed in computational super-resolution and the quality was of the same level as a digital holographic system with 40x magnification objective. Furthermore, the single-shot advantage provides the possibility to record dynamic scenes, where the framerate is limited only by the used camera. We provide amplitude-phase video clip of a moving alive single-celled eukaryote.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑