arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2108.02991cs.DC
收藏

优化高分辨率T2 * 加权磁共振成像的全三维SPARKLING轨迹

Optimizing full 3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance Imaging

Chaithya G R, Pierre Weiss, Guillaume Daval-Frérot, Aurélien Massire, Alexandre Vignaud, Philippe Ciuciu

摘要:

用于快速K空间采样的扩展投影算法(SPARKLING)是一种优化驱动的方法,最近引入用于使用压缩感知的加速2D T2*-w MRI。然后,它已被扩展到使用2D采样模式的堆栈或一次优化单个采样轨迹的局部3D策略来解决3D成像。2D SPARKLING实际上沿着规定的目标密度执行可变密度采样(VDS),同时最大化采样效率并满足基于梯度的硬件约束。然而,如果想要保持峰值点扩散函数(PSF)并因此保持良好的图像质量,则3D SPARKLING在沿第三维的加速因子方面仍然是有限的。在本文中,为了在保持图像质量的同时实现更高的3D成像加速因子,我们提出了一种新的高效算法,对全3D SPARKLING进行优化。基于快速多极子方法(FMM)的拟议实现允许我们设计具有多达10^7个k空间样本的采样模式,从而为3D VDS打开了大门。我们比较多CPU和GPU的实现,并证明后者是最佳的3D成像在高分辨率采集制度(600 $μ$ m各向同性)。最后,我们通过对NIST体模和3特斯拉体内脑部扫描的回顾性和前瞻性研究表明,这种针对全3D SPARKLING的新型优化优于堆叠策略或3D扭曲投影成像。总体而言,与GRAPPA-4并行成像采集相比,所提出的方法允许在3特斯拉下缩短2.5- 3.75倍的扫描时间,而不影响图像质量。

英文摘要:

The Spreading Projection Algorithm for Rapid K-space samplING, or SPARKLING, is an optimization-driven method that has been recently introduced for accelerated 2D T2*-w MRI using compressed sensing. It has then been extended to address 3D imaging using either stacks of 2D sampling patterns or a local 3D strategy that optimizes a single sampling trajectory at a time. 2D SPARKLING actually performs variable density sampling (VDS) along a prescribed target density while maximizing sampling efficiency and meeting the gradient-based hardware constraints. However, 3D SPARKLING has remained limited in terms of acceleration factors along the third dimension if one wants to preserve a peaky point spread function (PSF) and thus good image quality. In this paper, in order to achieve higher acceleration factors in 3D imaging while preserving image quality, we propose a new efficient algorithm that performs optimization on full 3D SPARKLING. The proposed implementation based on fast multipole methods (FMM) allows us to design sampling patterns with up to 10^7 k-space samples, thus opening the door to 3D VDS. We compare multi-CPU and GPU implementations and demonstrate that the latter is optimal for 3D imaging in the high-resolution acquisition regime (600$μ$m isotropic). Finally, we show that this novel optimization for full 3D SPARKLING outperforms stacking strategies or 3D twisted projection imaging through retrospective and prospective studies on NIST phantom and in vivo brain scans at 3 Tesla. Overall the proposed method allows for 2.5-3.75x shorter scan times compared to GRAPPA-4 parallel imaging acquisition at 3 Tesla without compromising image quality.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑