人工智能辅助轮廓修正的概念验证研究

A Proof-of-Concept Study of Artificial Intelligence Assisted Contour Revision

University of Texas Southwestern Medical Center(德克萨斯大学西南医学中心)

Ti Bai, Anjali Balagopal, Michael Dohopolski, Howard E. Morgan, Rafe McBeth, Jun Tan, Mu-Han Lin, David J. Sher, Dan Nguyen, Steve Jiang

摘要:

解剖结构的自动分割对于许多医学应用是至关重要的。然而,结果并不总是临床上可接受的,需要繁琐的手动修改。在这里,我们提出了一个新的概念,称为人工智能辅助轮廓修正(AIACR),并证明其可行性。AIACR的拟议临床工作流程如下:给定需要临床医生修正的初始轮廓,临床医生指示需要大修正的位置,并且经训练的深度学习(DL)模型采用该输入来更新轮廓。重复该过程,直到获得临床上可接受的轮廓。DL模型旨在最大限度地减少每次迭代时的临床医生输入,并最大限度地减少达到验收所需的迭代次数。在这项概念验证研究中,我们在三个头颈部癌症数据集的2D轴向图像上展示了这一概念,临床医生在每次迭代时的输入是在轮廓段的所需位置上单击鼠标。模型的性能用Dice相似系数(DSC)和Hausdorff距离的第95百分位数(HD 95)来量化。自动生成的初始轮廓的平均DSC/HD 95(mm)对于三个数据集分别为0.82/4.3、0.73/5.6和0.67/11.4,通过三次鼠标点击分别提高到0.91/2.1、0.86/2.4和0.86/4.7。每个基于DL的轮廓更新需要大约20毫秒。我们提出了一种新的AIACR概念,使用DL模型来帮助临床医生以高效和有效的方式修改轮廓,我们通过使用来自三个头颈部癌症数据集的2D轴向CT图像证明了其可行性。

英文摘要:

Automatic segmentation of anatomical structures is critical for many medical applications. However, the results are not always clinically acceptable and require tedious manual revision. Here, we present a novel concept called artificial intelligence assisted contour revision (AIACR) and demonstrate its feasibility. The proposed clinical workflow of AIACR is as follows given an initial contour that requires a clinicians revision, the clinician indicates where a large revision is needed, and a trained deep learning (DL) model takes this input to update the contour. This process repeats until a clinically acceptable contour is achieved. The DL model is designed to minimize the clinicians input at each iteration and to minimize the number of iterations needed to reach acceptance. In this proof-of-concept study, we demonstrated the concept on 2D axial images of three head-and-neck cancer datasets, with the clinicians input at each iteration being one mouse click on the desired location of the contour segment. The performance of the model is quantified with Dice Similarity Coefficient (DSC) and 95th percentile of Hausdorff Distance (HD95). The average DSC/HD95 (mm) of the auto-generated initial contours were 0.82/4.3, 0.73/5.6 and 0.67/11.4 for three datasets, which were improved to 0.91/2.1, 0.86/2.4 and 0.86/4.7 with three mouse clicks, respectively. Each DL-based contour update requires around 20 ms. We proposed a novel AIACR concept that uses DL models to assist clinicians in revising contours in an efficient and effective way, and we demonstrated its feasibility by using 2D axial CT images from three head-and-neck cancer datasets.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑