无造影剂CT上颅内颈动脉钙化的自动分割和体积测量
Automated Segmentation and Volume Measurement of Intracranial Carotid Artery Calcification on Non-Contrast CT
摘要:
目的:评价一种基于深度学习的全自动颅内颈动脉钙化(ICAC)评估方法。研究方法:在2003年至2006年前瞻性收集的鹿特丹研究的2,319名参与者(平均年龄69(SD 7)岁; 1154名女性)的非增强CT扫描中,两名观察员手动描绘了ICAC。这些数据用于回顾性地开发和验证基于深度学习的自动ICAC描绘和体积测量方法。为了评估该方法,我们比较了手动和自动评估(使用十倍交叉验证计算):1)与独立观察员评估(在47次扫描的随机子集中可用)的一致性; 2)通过专家盲法视觉比较判断的ICAC描绘准确性; 3)从扫描日期到2012年与首次卒中发病率的关联。使用10倍交叉验证计算所有方法性能指标。结果:ICAC自动勾画的敏感性为83.8%,阳性预测值(PPV)为88%。自动和手动ICAC体积测量之间的组内相关性为0.98(95% CI:0.97,0.98;在整个数据集中计算)。在独立观察者的评估之间测量,灵敏度为73.9%,PPV为89.5%,组内相关性为0.91(95% CI:0.84,0.95;在47次扫描子集中计算)。在设盲目视比较中,自动描绘比手动描绘更准确(p值= 0.01)。ICAC容量与卒中事件的关联性在自动测量容量(风险比,1.38(95% CI:1.12,1.75))和手动测量容量(风险比,1.48(95% CI:1.20,1.87))中同样强。结论:所开发的模型能够自动分割和ICAC的体积定量与人类专家的准确性。
英文摘要:
Purpose: To evaluate a fully-automated deep-learning-based method for assessment of intracranial carotid artery calcification (ICAC). Methods: Two observers manually delineated ICAC in non-contrast CT scans of 2,319 participants (mean age 69 (SD 7) years; 1154 women) of the Rotterdam Study, prospectively collected between 2003 and 2006. These data were used to retrospectively develop and validate a deep-learning-based method for automated ICAC delineation and volume measurement. To evaluate the method, we compared manual and automatic assessment (computed using ten-fold cross-validation) with respect to 1) the agreement with an independent observer's assessment (available in a random subset of 47 scans); 2) the accuracy in delineating ICAC as judged via blinded visual comparison by an expert; 3) the association with first stroke incidence from the scan date until 2012. All method performance metrics were computed using 10-fold cross-validation. Results: The automated delineation of ICAC reached sensitivity of 83.8% and positive predictive value (PPV) of 88%. The intraclass correlation between automatic and manual ICAC volume measures was 0.98 (95% CI: 0.97, 0.98; computed in the entire dataset). Measured between the assessments of independent observers, sensitivity was 73.9%, PPV was 89.5%, and intraclass correlation was 0.91 (95% CI: 0.84, 0.95; computed in the 47-scan subset). In the blinded visual comparisons, automatic delineations were more accurate than manual ones (p-value = 0.01). The association of ICAC volume with incident stroke was similarly strong for both automated (hazard ratio, 1.38 (95% CI: 1.12, 1.75) and manually measured volumes (hazard ratio, 1.48 (95% CI: 1.20, 1.87)). Conclusions: The developed model was capable of automated segmentation and volume quantification of ICAC with accuracy comparable to human experts.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。