arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2106.14739cs.CVcs.HC
收藏

基于卷积神经网络的智能步行机实时的人体姿态估计

Real-Time Human Pose Estimation on a Smart Walker using Convolutional Neural Networks

University of Minho(米尼奥大学);Center for Microelectromechanical Systems(微机电系统中心);Scuola Superiore Sant’Anna(圣安娜高等研究院);The BioRobotics Institute(生物机器人研究所);Università Politecnica delle Marche(马尔凯理工大学)

Manuel Palermo, Sara Moccia, Lucia Migliorelli, Emanuele Frontoni, Cristina P. Santos

摘要:

康复对于改善行动不便患者的生活质量非常重要。智能步行器是一种常用的解决方案,它应该嵌入自动和客观的工具,用于数据驱动的人在回路控制和监控。然而,目前的解决方案集中于从专用传感器提取很少的特定度量,而没有统一的全身方法。我们研究了一个通用的,实时的【形】,全身姿态估计框架的基础上,两个RGB+D相机流与非重叠的意见安装在一个智能步行设备用于康复。使用两阶段神经网络框架来执行人体关键点估计。2D-Stage实现了在2D图像帧中定位身体关键点的检测模块。3D-Stage实现了一个回归模块,该模块将两个摄像机中检测到的关键点提升并关联到相对于步行者的3D空间。模型预测经过低通滤波,以提高时间一致性。使用自定义采集方法获得具有14名健康受试者的数据集,用于离线训练和评估所提出的框架,然后将其部署在真实的步行器设备上。据报道,2D-Stage和3D-Stage的总体关键点检测误差分别为3.73像素和44.05 mm,在步行器的受限硬件上部署时,推理时间为26.6 ms。我们提出了一种新的方法,病人监测和数据驱动的人在环控制的背景下,智能步行机。它能够实时的【形】从廉价的传感器中提取完整而紧凑的身体表示,作为下游指标提取解决方案和人机交互应用的共同基础。尽管结果令人鼓舞,但应该收集更多关于有障碍的用户的数据,以评估其在现实世界中作为康复工具的性能。

英文摘要:

Rehabilitation is important to improve quality of life for mobility-impaired patients. Smart walkers are a commonly used solution that should embed automatic and objective tools for data-driven human-in-the-loop control and monitoring. However, present solutions focus on extracting few specific metrics from dedicated sensors with no unified full-body approach. We investigate a general, real-time, full-body pose estimation framework based on two RGB+D camera streams with non-overlapping views mounted on a smart walker equipment used in rehabilitation. Human keypoint estimation is performed using a two-stage neural network framework. The 2D-Stage implements a detection module that locates body keypoints in the 2D image frames. The 3D-Stage implements a regression module that lifts and relates the detected keypoints in both cameras to the 3D space relative to the walker. Model predictions are low-pass filtered to improve temporal consistency. A custom acquisition method was used to obtain a dataset, with 14 healthy subjects, used for training and evaluating the proposed framework offline, which was then deployed on the real walker equipment. An overall keypoint detection error of 3.73 pixels for the 2D-Stage and 44.05mm for the 3D-Stage were reported, with an inference time of 26.6ms when deployed on the constrained hardware of the walker. We present a novel approach to patient monitoring and data-driven human-in-the-loop control in the context of smart walkers. It is able to extract a complete and compact body representation in real-time and from inexpensive sensors, serving as a common base for downstream metrics extraction solutions, and Human-Robot interaction applications. Despite promising results, more data should be collected on users with impairments, to assess its performance as a rehabilitation tool in real-world scenarios.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑