arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2106.12889physics.ins-det
收藏

用于尺寸分辨颗粒计数和PM2 .5测量的低成本颗粒物传感器校准的复合物Refractive Index和颗粒密度值的评估

Assessing the Value of Complex Refractive Index and Particle Density for Calibration of Low-Cost Particle Matter Sensor for Size-Resolved Particle Count and PM2.5 Measurements

Ching-Hsuan Huang, Jiayang He, Elena Austin, Edmund Seto, Igor Novosselov

摘要:

市售低成本颗粒物(PM)传感器提供总颗粒物计数或特定尺寸颗粒物计数和质量浓度的输出。这些量不是直接测量的,而是通过原始设备制造商(OEM)的专有算法估计的,并且具有固有的局限性,因为颗粒散射取决于它们的成分、尺寸、形状和复折射率(CRI)。因此,需要在受控环境下表征和校准其性能。我们提出了校准算法的Plantower PMS A003传感器作为一个功能的颗粒大小和浓度。使用标准化实验方案来控制PM水平、环境条件并评估传感器到传感器的再现性。校准基于PMS A003暴露于不同多分散标准化测试气溶胶时的测试。结果表明,PMS A003的粒度分布与参考仪器测量值相比发生了偏移。对于数浓度的校准,未调整气溶胶特性的线性模型校正了特定尺寸箱的原始PMS A003测量值,归一化平均绝对误差在参考仪器的4.0%范围内。虽然贝叶斯信息准则表明,调整颗粒光学特性和相对湿度的模型在技术上更优越,但应谨慎使用,因为拟合中使用的颗粒特性在挑战气溶胶的窄范围内。针对颗粒CRI和密度调整的校准模型解释了OEM质量浓度估计值中的非线性,并显示出较低的误差。这些结果对于在高浓度环境中使用PMS A003具有重要意义,包括室内空气质量和职业/工业暴露评估,野火烟雾或近源监测场景。

英文摘要:

Commercially available low-cost particulate matter (PM) sensors provide output as total or size-specific particle counts and mass concentrations. These quantities are not measured directly but are estimated by the original equipment manufacturers' (OEM) proprietary algorithms and have inherent limitations since particle scattering depends on their composition, size, shape, and complex index of refraction (CRI). Hence, there is a need to characterize and calibrate their performance under a controlled environment. We present calibration algorithms for Plantower PMS A003 sensor as a function of particle size and concentration. A standardized experimental protocol was used to control the PM level, environmental conditions and to evaluate sensor-to-sensor reproducibility. The calibration was based on tests when PMS A003 were exposed to different polydisperse standardized testing aerosols. The results suggested particle size distribution from PMS A003 was shifted compared to reference instrument measures. For calibration of number concentration, linear model without adjusting aerosol properties corrects the raw PMS A003 measurement for specific size bins with normalized mean absolute error within 4.0% of the reference instrument. Although the Bayesian Information Criterion suggests that models adjusting for particle optical properties and relative humidity are technically superior, they should be used with caution as the particle properties used in fitting were within a narrow range for challenge aerosols. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM's mass concentrations estimates and demonstrated lower error. These results have significant implications for using PMS A003 in high concentration environments, including indoor air quality and occupational/industrial exposure assessments, wildfire smoke, or near-source monitoring scenarios.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑