用于汤姆逊散射光谱仪绝对校准的二氧化硅拉曼散射探针
Silica Raman scattering probe for absolute calibration of Thomson scattering spectrometers
摘要:
我们已经开发了一个固态探头的绝对辐照度校准的汤姆逊散射系统的大型等离子体装置(LAPD)的基础上,拉曼散射关闭二氧化硅。用三重光栅光谱仪进行的测量研究了在与LAPD(299 - 498 K)相关的温度范围内的脉冲激光束拉曼散射离开结晶和非晶二氧化硅的强度。将数据与气态氮中的瑞利和拉曼散射强度进行了比较。测量结果表明,拉曼散射石英允许快速和准确的校准和校准的汤姆逊散射系统在等离子体物理实验,不能使用传统的方法进行校准。
英文摘要:
We have developed a solid state probe for an absolute irradiance calibration of the Thomson scattering system on the Large Plasma Device (LAPD), based on Raman scattering off silica. Measurements performed with a triple-grating spectrometer have investigated the intensities of a pulsed laser beam Raman scattered off crystalline and amorphous silica over a range of temperatures of relevance to the LAPD (299 - 498 K). The data were compared with Rayleigh and Raman scattering intensities in gaseous nitrogen. The measurements show that Raman scattering off quartz allows rapid and accurate alignment and calibration of Thomson scattering systems in plasma physics experiments that cannot be calibrated using conventional methods.