时间卷积网络预测运动强度下可穿戴传感器的动态摄氧量响应
Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities
摘要:
耗氧量(VO $_2$)提供了心肺功能和运动能力的既定临床和生理指标。然而,VO $_2$监测在很大程度上限于专业实验室环境,使得其广泛监测难以实现。在这里,我们调查的时间预测VO $_2$从可穿戴传感器在自行车测力计运动使用时间卷积网络(TCN)。从22名年轻健康成年人的代谢系统中采集了带有集成纺织传感器的智能衬衫以及地面实况VO $_2$的呼吸信号。参与者进行了一个斜坡增量和三个伪随机二进制序列运动协议,以评估一系列VO $_2$动态。一个TCN模型的开发使用因果卷积在一个有效的历史长度来模拟VO $_2$的时间依赖性。通过超参数值的最小验证损失确定最佳历史长度。表现最好的模型编码218 s的历史长度(TCN-VO $_2$ A),187 s,97 s和76 s产生小于3%的偏差,从最佳验证损失。TCN-VO $_2$ A显示出较强的预测准确性(平均值,95% CI)(-22 ml.min $^{-1}$,[-262,218]),从低-中度过渡(-23 ml.min $^{-1}$,[-250,204]),低-高(14 ml.min $^{-1}$,[-252,280])、训练阈值高(-49 ml.min $^{-1}$,[-274,176])和最大(-32 ml.min $^{-1}$,[-261,197])运动。在16090秒的预测VO $_2$中,对身体活动的逐秒分类能够以高准确度(94.1%)区分剧烈、中度和轻度活动。该系统使用可穿戴传感器在非实验室环境中跨一系列运动强度进行定量有氧活动监测,以监测运动处方依从性和个人健身。
英文摘要:
Oxygen consumption (VO$_2$) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, VO$_2$ monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here, we investigate temporal prediction of VO$_2$ from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth VO$_2$ from a metabolic system on twenty-two young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of VO$_2$ dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of VO$_2$. Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO$_2$ A), with 187 s, 97 s, and 76 s yielding less than 3% deviation from the optimal validation loss. TCN-VO$_2$ A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (-22 ml.min$^{-1}$, [-262, 218]), spanning transitions from low-moderate (-23 ml.min$^{-1}$, [-250, 204]), low-high (14 ml.min$^{-1}$, [-252, 280]), ventilatory threshold-high (-49 ml.min$^{-1}$, [-274, 176]), and maximal (-32 ml.min$^{-1}$, [-261, 197]) exercise. Second-by-second classification of physical activity across 16090 s of predicted VO$_2$ was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。