生成模型提高低剂量CT放射组学再现性的模拟研究
Generative Models Improve Radiomics Reproducibility in Low Dose CTs: A Simulation Study
摘要:
放射组学是医学图像分析领域的一个活跃的研究领域,但放射组学的低重复性限制了其在临床上的应用。当从噪声图像(诸如低剂量计算机断层摄影(CT)扫描)计算放射组学特征时,该问题尤其突出。在这篇文章中,我们研究了通过使用生成模型去噪来提高噪声CT上计算的放射组学特征的再现性的可能性,一种传统的去噪方法-非局部均值-和两种生成模型-编码器-解码器网络(EDN)和条件生成对抗网络(CGAN)-被选为测试模型。我们将噪声添加到全剂量CT的正弦图中,以模拟具有两种不同噪声水平的低剂量CT:低噪声CT和高噪声CT。模型在高噪声CT上进行训练,并用于对低噪声CT进行降噪,而无需重新训练。我们还测试了我们的模型在真实数据中的性能,使用同一天重复低剂量CT的数据集来评估去噪图像中放射组学特征的再现性。EDN和CGAN分别将低噪声图像和高噪声图像的辐射组学特征的一致性相关系数(CCC)从0.87提高到0.92,从0.68提高到0.92。此外,EDN和CGAN提高了基于真实低剂量CT的放射组学特征的重测信度(平均CCC从0.89增加到0.94)。结果表明,使用EDN和CGAN去噪可以提高在有噪CT上计算的放射组学特征的再现性。此外,具有不同噪声水平的图像可以被去噪,以提高使用这些模型的再现性,而无需重新训练,只要噪声强度等于或低于高噪声CT中的噪声强度。据作者所知,这是第一次努力提高低剂量CT扫描计算的放射组学特征的再现性。
英文摘要:
Radiomics is an active area of research in medical image analysis, the low reproducibility of radiomics has limited its applicability to clinical practice. This issue is especially prominent when radiomic features are calculated from noisy images, such as low dose computed tomography (CT) scans. In this article, we investigate the possibility of improving the reproducibility of radiomic features calculated on noisy CTs by using generative models for denoising.One traditional denoising method - non-local means - and two generative models - encoder-decoder networks (EDN) and conditional generative adversarial networks (CGANs) - were selected as the test models. We added noise to the sinograms of full dose CTs to mimic low dose CTs with two different levels of noise: low-noise CT and high-noise CT. Models were trained on high-noise CTs and used to denoise low-noise CTs without re-training. We also test the performance of our model in real data, using dataset of same-day repeat low dose CTs to assess the reproducibility of radiomic features in denoised images. The EDN and the CGAN improved the concordance correlation coefficients (CCC) of radiomic features for low-noise images from 0.87 to 0.92 and for high-noise images from 0.68 to 0.92 respectively. Moreover, the EDN and the CGAN improved the test-retest reliability of radiomic features (mean CCC increased from 0.89 to 0.94) based on real low dose CTs. The results show that denoising using EDN and CGANs can improve the reproducibility of radiomic features calculated on noisy CTs. Moreover, images with different noise levels can be denoised to improve the reproducibility using these models without re-training, as long as the noise intensity is equal or lower than that in high-noise CTs. To the authors' knowledge, this is the first effort to improve the reproducibility of radiomic features calculated on low dose CT scans.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。