arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2104.13167cs.RO
收藏

Festo执行器位置和刚度混合控制的逆静态模型

Towards an efficient inverse static model of a Festo actuator made of two antagonist muscles for hybrid control of its position and stiffness

INSA de Toulouse(图卢兹国立应用科学学院);LAAS/CNRS(法国国家科学研究中心图卢兹实验室)

Bertrand Tondu

摘要:

Festo空气肌肉是当今最知名的商业版本的所谓McKibben气动人工肌肉之一。手工制作的McKibben肌肉及其商业版本的主要优点在于它提供了在二头肌-三头肌系统的模型上实现拮抗肌致动器的可能性。如果在每个人工肌肉中独立地控制压力,则可以通过与拮抗剂骨骼肌的自然神经控制类比来定义拮抗剂致动器的位置刚度控制。然而,这样的控制需要致动器的知识模型,使得由控制压力提供的刚度估计成为可能,而位置闭环控制通过该高度非线性致动装置的前馈模型来促进。我们讨论了这个问题的具体情况下,拮抗剂Festo空气肌肉驱动器,我们提出了一个简化的静态致动器模型来自经典的静态理论模型的McKibben人工肌肉,对于未来的MIMO位置来说足够简单-如果所提出的模型突出了拮抗剂Festo肌肉致动器通过以下方式模仿刚度神经控制的能力,由于Festo肌肉是人工肌肉内部压力的总和,因此也很难推导出一个简单但准确的模型来描述Festo肌肉在压力的整个控制范围内产生的静态力。报告的结果表明,这将是特别有趣的是,从众多的研究Festo肌肉建模的优势,以进一步找到这样的逆致动器模型,包括一个准确的估计的致动器刚度。

英文摘要:

The Festo air muscle is today one of the most known commercial version of the so-called McKibben pneumatic artificial muscle. A major advantage of handmade McKibben muscles, as well as its commercial versions, lies in the possibility it offers of realizing antagonist muscle actuator on the model of the biceps-triceps system. If pressures are independently controlled in each artificial muscle, it is then possible to define a position-stiffness control of the antagonist actuator by analogy with natural neural control of antagonist skeletal muscles. Such a control however requires a knowledge model of the actuator making possible a stiffness estimation provided by control pressures, while position closed-loop control is facilitated by a feedforward model of this highly nonlinear actuation device. We discuss this issue in the particular case of the antagonist Festo air muscle actuator, and we propose a simplified static actuator model derived from the classic static theoretical model of the McKibben artificial muscle, simple enough for a future MIMO position-stiffness controller be able to integrate it. If the proposed model highlights the ability of the antagonist Festo muscle actuator to mimic the stiffness neural control by the mean of the sum of pressures inside artificial muscles, it also highlights the difficulty to derive a simple but accurate model of the static force produced by Festo muscle in the full control range of pressure. The reported results suggest that it would be particularly interesting to derive advantage from numerous studies about Festo muscle modelling to go further in order to find such an inverse actuator model including an accurate estimation of the actuator stiffness.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑