有源配电网故障检测与定位中PMU的最优配置
Optimal Positioning of PMUs for Fault Detection and Localization in Active Distribution Networks
摘要:
本文研究了基于PMU的有源配电网故障检测与定位问题。所提出的算法包括在计算一组加权最小二乘状态估计,其结果被用来检测,表征和定位故障的发生。此外,一个标准,以尽量减少正确执行所提出的算法所需的PMU的数量被定义。这样的标准,基于系统的可观测性条件,允许设计的优化问题,以设置沿电网的PMU的位置,以获得所需的故障定位解决方案。该策略的性能进行了测试,通过模拟的基准配电系统。
英文摘要:
This paper considers the problem of fault detection and localization in active distribution networks using PMUs. The proposed algorithm consists in computing a set of weighted least squares state estimates whose results are used to detect, characterize and localize the occurrence of a fault. Moreover, a criteria to minimize the number of PMUs required to correctly perform the proposed algorithm is defined. Such a criteria, based on system observability conditions, allows the design of an optimization problem to set the positions of PMUs along the grid, in order to get the desired fault localization resolution. The performances of the strategy are tested via simulations on a benchmark distribution system.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。