arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2103.17227cond-mat.mtrl-sci
收藏

热极化PET驻极体的电声脉冲和热激励去极化电流测量的比较

Comparison of pulsed electroacoustic and thermally stimulated depolarization current measurements of thermally poled PET electrets

S. E. Parsa, J. C. Cañadas, J. A. Diego, M. Mudarra, J. Sellarès

摘要:

我们比较了一组聚对苯二甲酸乙二醇酯(PET)驻极体样品的脉冲电声法(PEA)和热刺激去极化电流(TSDC)技术的测量。实验参数,如组合的热和电的历史和电极类型已被选定,以相关的极化机制,揭示了TSDC与PEA测量的电荷分布在五种不同的情况下。PEA的现有去卷积程序已被改进为在薄样品的情况下增强PEA信号的校准的手段。其中$α$偶极弛豫或$ρ$空间电荷弛豫被激活的样品显示出均匀的极化,其本身表现为电极处的图像电荷。在将外部载流子注入样品的实验中,在不同的电极配置下测试了相同的极化过程。电荷分布在所有这些定性相似,但去极化电流表现出明显不同的行为。这些差异一方面通过真空沉积的铝电极相对于具有薄气隙的电极的不同阻挡行为来解释,另一方面通过具有气隙的电极对于载流子的两个方向的不同行为来解释。TSDC峰的极化和每单位面积的电荷分布的电荷的数值分析支持这种解释,并确认两种测量技术之间的关系。总之,PEA与TSDC相结合的结果是一个有用的技术在热极化驻极体的研究,无论是在弛豫或外部电荷的研究。

英文摘要:

We have compared measurements of a set of polyethylene terephthalate (PET) electret samples by means of pulsed electroacoustic method (PEA) and thermally stimulated depolarization current (TSDC) techniques. Experimental parameters such as the combined thermal and electrical history and the electrode type have been selected in order to correlate the polarization mechanisms revealed by TSDC with the charge profile measured by PEA in five different cases. Existing deconvolution procedures for PEA have been improved as a means to enhance the calibration of PEA signals in the case of thin samples. Samples where the $α$ dipolar relaxation or the $ρ$ space charge relaxation is activated show a uniform polarization that manifests itself as image charge at the electrodes. In the experiments where external charge carriers are injected into the sample, the same poling procedure has been tested under different electrode configurations. Charge profiles are qualitatively similar in all of them but the depolarization currents show clearly different behavior. These differences are explained, on the one hand, by the different blocking behavior of vacuum-deposited aluminum electrodes with regards to electrodes with a thin air gap and, on the other hand, by the distinct behavior of electrodes with an air gap for both directions of the charge carriers. Numerical analysis of the polarization of TSDC peaks and charge per unit area of charge profiles supports this interpretation and confirms the relationship between both measurement techniques. All in all, PEA in combination with TSDC turns out to be a useful technique in the study of thermally poled electrets, either in the study of relaxations or of external charge.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑